CivilAxisCivilAxis
☕ Support🌐 Community

IPE AA 240 - Section Properties

The IPE AA 240 is a European I-beam (IPE) with a mass of 24.9 kg/m, an overall depth of 236.4 mm and width of 120 mm. It has a cross-sectional area of 31.7 cm², a second moment of area Iᵧ of 3150 cm⁴, a plastic modulus Wₚₗ,ᵧ of 298 cm³, tabulated by CivilAxis from EN 10365 · Continental Steel.

Mass
24.9 kg/m
Depth
236.4 mm
Width
120 mm
Area
31.7 cm²
Ask about capacity, buckling or detailing for IPE AA 240.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
IPE section profile showing the dimension symbols used for IPE AA 240

Dimension symbols for IPE sections. Not to scale.

IPE AA 240 section properties to EN 10365 · Continental Steel.

Geometry

Depth of sectionh236.4
Width of sectionb120
Web thicknesstw4.8
Flange thicknesstf8
Root fillet radiusr15
Depth between filletsd190.4

Mass and area

Mass per metremass24.9
Cross-sectional areaA31.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3150
Elastic section modulus about y-axisWel,y267
Plastic section modulus about y-axisWpl,y298
Radius of gyration about y-axisiy9.97

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz231
Elastic section modulus about z-axisWel,z39
Plastic section modulus about z-axisWpl,z60
Radius of gyration about z-axisiz2.7

Torsion and warping

Torsion constant (St Venant)It7.61
Warping constantIw0.0301

Classification and stability

Flange local-buckling ratiocf/tf5.33
Web local-buckling ratiocw/tw39.7
Buckling parameteru4.949
Torsional indexX26.4

Detailing dimensions

End clearanceC4
Notch dimension NN68
Notch dimension nn24

Surface area

Surface area per metreSA/m0.917

Is IPE AA 240 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending34%
36.1 / 105.8 kNm
Shear10%
32.1 / 313.3 kN
Deflection61%
7.7 / 12.5 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about IPE AA 240

IPE AA 240 has a mass of 24.9 kg/m, tabulated to EN 10365. A 12 m length therefore weighs about 299 kg, which is the figure to use for a steel take-off or when checking a lift.

IPE AA 240 has a depth of 236.4 mm, a width of 120 mm, a web thickness of 4.8 mm, a flange thickness of 8 mm, with a cross-sectional area of 31.7 cm². These are the nominal dimensions from EN 10365; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 298 cm³, and the elastic modulus Wel,y is 267 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 106 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,150 cm⁴, and about the minor axis Iz is 231 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.33 for the flange and cw/tw = 39.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.97 cm about the major axis and iz is 2.7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.7 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 7.61 cm⁴, and the warping constant Iw is 0.0301 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related IPE sizes

IPE AA 220IPE A 220IPE 220IPE O 220IPE A 240IPE 240IPE O 240IPE A 270

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All IPE sizes
European I-Beams (IPE)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…