CivilAxisCivilAxis
☕ Support🌐 Community

LC 60x30x10-1.62 - Section Properties

The LC 60x30x10-1.62 is a cold-formed lipped channel with a mass of 1.62 kg/m, a wall thickness of 1.6 mm. It has a cross-sectional area of 2.05 cm², a second moment of area Iᵧ of 11.4 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4.48 cm³, tabulated by CivilAxis from Continental Steel.

Mass
1.62 kg/m
Wall thickness
1.6 mm
Area
2.05 cm²
Ask about capacity, buckling or detailing for LC 60x30x10-1.62.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Lipped Channel section profile showing the dimension symbols used for LC 60x30x10-1.62

Dimension symbols for Lipped Channel sections. Not to scale.

LC 60x30x10-1.62 section properties to Continental Steel.

Geometry

Wall thicknesst1.6
Root fillet radiusr4
Toe radiusr22.4

Mass and area

Mass per metremass1.62
Cross-sectional areaA2.05

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy11.4
Elastic section modulus about y-axisWel,y3.81
Plastic section modulus about y-axisWpl,y4.48
Radius of gyration about y-axisiy2.36

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2.5
Elastic section modulus about z-axisWel,z1.29
Plastic section modulus about z-axisWpl,z2.12
Radius of gyration about z-axisiz1.1

Torsion and warping

Torsion constant (St Venant)It0.0182
Warping constantIw0.0219

Classification and stability

Buckling parameteru0.808
Torsional indexX35.5

Detailing dimensions

Centroid distance from back of leg (y)cy1.06

Common questions about LC 60x30x10-1.62

LC 60x30x10-1.62 has a mass of 1.62 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 19 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 4.48 cm³, and the elastic modulus Wel,y is 3.81 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2 kNm before any stability check.

The second moment of area about the major axis, Iy, is 11.4 cm⁴, and about the minor axis Iz is 2.5 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.36 cm about the major axis and iz is 1.1 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 1.1 cm a 0.1 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 0.018 cm⁴, and the warping constant Iw is 0.0219 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related Lipped Channel sizes

LC 60x30x10-2.25LC 75x45x15-2.31LC 75x45x15-3.24LC 75x45x15-4.12LC 75x45x15-4.37LC 100x50x20-2.88LC 100x50x20-4.06LC 100x50x20-5.18

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All Lipped Channel sizes
Lipped Channels (cold-formed)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.