H-125x125x6.5x9-23.8 - Section Properties

The H-125x125x6.5x9-23.8 is a European narrow I-beam with a mass of 23.8 kg/m, an overall depth of 125 mm and width of 125 mm. It has a cross-sectional area of 30.3 cm², a second moment of area Iᵧ of 847 cm⁴, a plastic modulus Wₚₗ,ᵧ of 154 cm³, tabulated by CivilAxis from Continental Steel.

Mass
23.8 kg/m
Depth
125 mm
Width
125 mm
Area
30.3 cm²
Ask about capacity, buckling or detailing for H-125x125x6.5x9-23.8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-125x125x6.5x9-23.8

Dimension symbols for MB & MC sections. Not to scale.

H-125x125x6.5x9-23.8 section properties to Continental Steel.

Geometry

Depth of sectionh125
Width of sectionb125
Web thicknesstw6.5
Flange thicknesstf9
Root fillet radiusr10
Depth between filletsd87

Mass and area

Mass per metremass23.8
Cross-sectional areaA30.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy847
Elastic section modulus about y-axisWel,y136
Plastic section modulus about y-axisWpl,y154
Radius of gyration about y-axisiy5.29

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz294
Elastic section modulus about z-axisWel,z47
Plastic section modulus about z-axisWpl,z71.9
Radius of gyration about z-axisiz3.11

Torsion and warping

Torsion constant (St Venant)It8.43
Warping constantIw0.01

Classification and stability

Flange local-buckling ratiocf/tf6.94
Web local-buckling ratiocw/tw13.4
Buckling parameteru0.84
Torsional indexX12.5

Detailing dimensions

End clearanceC5
Notch dimension NN69
Notch dimension nn19

Surface area

Surface area per metreSA/m0.72

Is H-125x125x6.5x9-23.8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending32%
17.6 / 54.7 kNm
Shear13%
28.1 / 208.8 kN
Deflection62%
4.3 / 6.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-125x125x6.5x9-23.8

H-125x125x6.5x9-23.8 has a mass of 23.8 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 286 kg, which is the figure to use for a steel take-off or when checking a lift.

H-125x125x6.5x9-23.8 has a depth of 125 mm, a width of 125 mm, a web thickness of 6.5 mm, a flange thickness of 9 mm, with a cross-sectional area of 30.3 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 154 cm³, and the elastic modulus Wel,y is 136 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 55 kNm before any stability check.

The second moment of area about the major axis, Iy, is 847 cm⁴, and about the minor axis Iz is 294 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.94 for the flange and cw/tw = 13.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 5.29 cm about the major axis and iz is 3.11 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.11 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 8.43 cm⁴, and the warping constant Iw is 0.01 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-100x100x6x8-16.9H-100x100x6x8-17.2H-125x60x6x8H-125x125x6.5x9-23.6H-150x75x5x7H-150x100x6x9-20.7H-150x100x6x9-21.1H-150x150x7x10-31.1

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…