CivilAxisCivilAxis
☕ Support🌐 Community

H-450x300x11x18-124 - Section Properties

The H-450x300x11x18-124 is a European narrow I-beam with a mass of 124 kg/m, an overall depth of 440 mm and width of 300 mm. It has a cross-sectional area of 157 cm², a second moment of area Iᵧ of 56070 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2825 cm³, tabulated by CivilAxis from Continental Steel.

Mass
124 kg/m
Depth
440 mm
Width
300 mm
Area
157 cm²
Ask about capacity, buckling or detailing for H-450x300x11x18-124.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-450x300x11x18-124

Dimension symbols for MB & MC sections. Not to scale.

H-450x300x11x18-124 section properties to Continental Steel.

Geometry

Depth of sectionh440
Width of sectionb300
Web thicknesstw11
Flange thicknesstf18
Root fillet radiusr24
Depth between filletsd356

Mass and area

Mass per metremass124
Cross-sectional areaA157

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy56070
Elastic section modulus about y-axisWel,y2549
Plastic section modulus about y-axisWpl,y2825
Radius of gyration about y-axisiy18.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz8114
Elastic section modulus about z-axisWel,z541
Plastic section modulus about z-axisWpl,z828
Radius of gyration about z-axisiz7.18

Torsion and warping

Torsion constant (St Venant)It163
Warping constantIw3.61

Classification and stability

Flange local-buckling ratiocf/tf8.33
Web local-buckling ratiocw/tw32.4
Buckling parameteru0.887
Torsional indexX23.4

Detailing dimensions

End clearanceC8
Notch dimension NN155
Notch dimension nn42

Surface area

Surface area per metreSA/m2.02

Is H-450x300x11x18-124 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
318.9 / 1002.9 kNm
Shear12%
141.8 / 1222.0 kN
Deflection61%
15.2 / 25.0 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-450x300x11x18-124

H-450x300x11x18-124 has a mass of 124 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1488 kg, which is the figure to use for a steel take-off or when checking a lift.

H-450x300x11x18-124 has a depth of 440 mm, a width of 300 mm, a web thickness of 11 mm, a flange thickness of 18 mm, with a cross-sectional area of 157 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,825 cm³, and the elastic modulus Wel,y is 2,549 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1003 kNm before any stability check.

The second moment of area about the major axis, Iy, is 56,070 cm⁴, and about the minor axis Iz is 8,114 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.33 for the flange and cw/tw = 32.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 18.9 cm about the major axis and iz is 7.18 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.18 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 163 cm⁴, and the warping constant Iw is 3.61 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-450x200x11x19H-450x200x14x19H-450x300x10x15H-450x300x11x18-121H-450x300x13x21H-500x200x9x14-77.9H-500x200x9x14-79.5H-500x200x10x16-88.2

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…