H-600x200x13x23 - Section Properties

The H-600x200x13x23 is a European narrow I-beam with a mass of 134 kg/m, an overall depth of 612 mm and width of 202 mm. It has a cross-sectional area of 171 cm², a second moment of area Iᵧ of 103500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3893 cm³, tabulated by CivilAxis from Continental Steel.

Mass
134 kg/m
Depth
612 mm
Width
202 mm
Area
171 cm²
Ask about capacity, buckling or detailing for H-600x200x13x23.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-600x200x13x23

Dimension symbols for MB & MC sections. Not to scale.

H-600x200x13x23 section properties to Continental Steel.

Geometry

Depth of sectionh612
Width of sectionb202
Web thicknesstw13
Flange thicknesstf23
Root fillet radiusr22
Depth between filletsd522

Mass and area

Mass per metremass134
Cross-sectional areaA171

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy103500
Elastic section modulus about y-axisWel,y3382
Plastic section modulus about y-axisWpl,y3893
Radius of gyration about y-axisiy24.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3178
Elastic section modulus about z-axisWel,z315
Plastic section modulus about z-axisWpl,z498
Radius of gyration about z-axisiz4.32

Torsion and warping

Torsion constant (St Venant)It237
Warping constantIw2.76

Classification and stability

Flange local-buckling ratiocf/tf4.39
Web local-buckling ratiocw/tw40.2
Buckling parameteru0.873
Torsional indexX28.3

Detailing dimensions

End clearanceC9
Notch dimension NN105
Notch dimension nn45

Surface area

Surface area per metreSA/m1.97

Is H-600x200x13x23 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
432.0 / 1382.0 kNm
Shear8%
144.0 / 1869.0 kN
Deflection60%
19.9 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-600x200x13x23

H-600x200x13x23 has a mass of 134 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1608 kg, which is the figure to use for a steel take-off or when checking a lift.

H-600x200x13x23 has a depth of 612 mm, a width of 202 mm, a web thickness of 13 mm, a flange thickness of 23 mm, with a cross-sectional area of 171 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,893 cm³, and the elastic modulus Wel,y is 3,382 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1382 kNm before any stability check.

The second moment of area about the major axis, Iy, is 103,500 cm⁴, and about the minor axis Iz is 3,178 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.39 for the flange and cw/tw = 40.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 24.6 cm about the major axis and iz is 4.32 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.32 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 237 cm⁴, and the warping constant Iw is 2.76 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-600x200x11x17-103H-600x200x11x17-106H-600x200x12x20-118H-600x200x12x20-120H-600x300x12x17-133H-600x300x12x17-137H-600x300x12x20-147H-600x300x12x20-151

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 610×229×125vs W 24X84

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…