CivilAxisCivilAxis
☕ Support🌐 Community

H-700x300x13x20 - Section Properties

The H-700x300x13x20 is a European narrow I-beam with a mass of 166 kg/m, an overall depth of 692 mm and width of 300 mm. It has a cross-sectional area of 211 cm², a second moment of area Iᵧ of 172400 cm⁴, a plastic modulus Wₚₗ,ᵧ of 5629 cm³, tabulated by CivilAxis from Continental Steel.

Mass
166 kg/m
Depth
692 mm
Width
300 mm
Area
211 cm²
Ask about capacity, buckling or detailing for H-700x300x13x20.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-700x300x13x20

Dimension symbols for MB & MC sections. Not to scale.

H-700x300x13x20 section properties to Continental Steel.

Geometry

Depth of sectionh692
Width of sectionb300
Web thicknesstw13
Flange thicknesstf20
Root fillet radiusr28
Depth between filletsd596

Mass and area

Mass per metremass166
Cross-sectional areaA211

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy172400
Elastic section modulus about y-axisWel,y4984
Plastic section modulus about y-axisWpl,y5629
Radius of gyration about y-axisiy28.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz9030
Elastic section modulus about z-axisWel,z602
Plastic section modulus about z-axisWpl,z936
Radius of gyration about z-axisiz6.53

Torsion and warping

Torsion constant (St Venant)It260
Warping constantIw10.2

Classification and stability

Flange local-buckling ratiocf/tf7.5
Web local-buckling ratiocw/tw45.8
Buckling parameteru0.878
Torsional indexX34.3

Detailing dimensions

End clearanceC9
Notch dimension NN154
Notch dimension nn48

Surface area

Surface area per metreSA/m2.51

Is H-700x300x13x20 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending36%
729.0 / 1998.3 kNm
Shear11%
243.0 / 2148.0 kN
Deflection60%
20.1 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-700x300x13x20

H-700x300x13x20 has a mass of 166 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1992 kg, which is the figure to use for a steel take-off or when checking a lift.

H-700x300x13x20 has a depth of 692 mm, a width of 300 mm, a web thickness of 13 mm, a flange thickness of 20 mm, with a cross-sectional area of 211 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 5,629 cm³, and the elastic modulus Wel,y is 4,984 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1998 kNm before any stability check.

The second moment of area about the major axis, Iy, is 172,400 cm⁴, and about the minor axis Iz is 9,030 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.5 for the flange and cw/tw = 45.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 28.6 cm about the major axis and iz is 6.53 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 6.53 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 260 cm⁴, and the warping constant Iw is 10.2 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-600x300x14x23-170H-600x300x14x23-175H-600x300x16x27H-600x300x16x30H-700x300x13x24-182H-700x300x13x24-185H-700x300x15x28H-800x300x14x22

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 686×254×170vs W 27X114

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…