CivilAxisCivilAxis
☕ Support🌐 Community

2×PFC 200×75×23 Back to Back - Section Properties

The 2×PFC 200×75×23 Back to Back is a parallel flange channel with a mass of 46.9 kg/m. It has a cross-sectional area of 59.7 cm², a second moment of area Iᵧ of 3930 cm⁴, a plastic modulus Wₚₗ,ᵧ of 464 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
46.9 kg/m
Area
59.7 cm²
Ask about capacity, buckling or detailing for 2×PFC 200×75×23 Back to Back.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC Back to Back section profile showing the dimension symbols used for 2×PFC 200×75×23 Back to Back

Dimension symbols for PFC Back to Back sections. Not to scale.

2×PFC 200×75×23 Back to Back section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Mass and area

Mass per metremass46.9
Cross-sectional areaA59.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3930
Elastic section modulus about y-axisWel,y393
Plastic section modulus about y-axisWpl,y464
Radius of gyration about y-axisiy8.11

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3130
Elastic section modulus about z-axisWel,z234
Plastic section modulus about z-axisWpl,z332
Radius of gyration about z-axisiz3.74

Common questions about 2×PFC 200×75×23 Back to Back

2×PFC 200×75×23 Back to Back has a mass of 46.9 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 563 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 464 cm³, and the elastic modulus Wel,y is 393 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 165 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,930 cm⁴, and about the minor axis Iz is 3,130 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 8.11 cm about the major axis and iz is 3.74 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.74 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related PFC Back to Back sizes

2×PFC 260×75×28 Back to Back2×PFC 230×90×32 Back to Back2×PFC 230×75×26 Back to Back2×PFC 200×90×30 Back to Back2×PFC 180×90×26 Back to Back2×PFC 180×75×20 Back to Back2×PFC 150×90×24 Back to Back2×PFC 150×75×18 Back to Back

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All PFC Back to Back sizes
Two PFC - Back to Back
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…