CivilAxisCivilAxis
☕ Support🌐 Community

2×PFC 300×100×45 Laced - Section Properties

The 2×PFC 300×100×45 Laced is a parallel flange channel with a mass of 91.1 kg/m. It has a cross-sectional area of 116 cm², a second moment of area Iᵧ of 16500 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1280 cm³, tabulated by CivilAxis from BS EN 1993-1-1:2005 / BS 4-1:2005 (SCI P363 Blue Book).

Mass
91.1 kg/m
Area
116 cm²
Ask about capacity, buckling or detailing for 2×PFC 300×100×45 Laced.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
PFC Laced section profile showing the dimension symbols used for 2×PFC 300×100×45 Laced

Dimension symbols for PFC Laced sections. Not to scale.

2×PFC 300×100×45 Laced section properties to BS EN 1993-1-1:2005 / BS 4-1:2005.

Mass and area

Mass per metremass91.1
Cross-sectional areaA116

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy16500
Elastic section modulus about y-axisWel,y1100
Plastic section modulus about y-axisWpl,y1280
Radius of gyration about y-axisiy11.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz16600
Elastic section modulus about z-axisWel,z898
Plastic section modulus about z-axisWpl,z1340
Radius of gyration about z-axisiz11.9

Common questions about 2×PFC 300×100×45 Laced

2×PFC 300×100×45 Laced has a mass of 91.1 kg/m, tabulated to BS EN 1993-1-1:2005 / BS 4-1:2005. A 12 m length therefore weighs about 1093 kg, which is the figure to use for a steel take-off or when checking a lift.

The plastic section modulus about the major axis, Wpl,y, is 1,280 cm³, and the elastic modulus Wel,y is 1,100 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 454 kNm before any stability check.

The second moment of area about the major axis, Iy, is 16,500 cm⁴, and about the minor axis Iz is 16,600 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11.9 cm about the major axis and iz is 11.9 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 11.9 cm a 1.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related PFC Laced sizes

2×PFC 430×100×64 Laced2×PFC 380×100×54 Laced2×PFC 300×90×41 Laced2×PFC 260×90×35 Laced2×PFC 260×75×28 Laced2×PFC 230×90×32 Laced2×PFC 230×75×26 Laced2×PFC 200×90×30 Laced

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)