RHS 120×60×10 - Section Properties
The RHS 120×60×10 is a rectangular hollow section with a mass of 24.3 kg/m, an overall depth of 120 mm and width of 60 mm and a wall thickness of 10 mm. It has a cross-sectional area of 30.9 cm², a second moment of area Iᵧ of 488 cm⁴, a plastic modulus Wₚₗ,ᵧ of 109 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for RHS 120×60×10.
or pick a unit on any row

Dimension symbols for RHS Hot-finished sections. Not to scale.
Is RHS 120×60×10 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 61% utilised, deflection governs
Bending26%
10.0 / 38.7 kNmShear4%
15.9 / 422.2 kNDeflection61%
4.2 / 6.9 mmClass 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.