CivilAxisCivilAxis
☕ Support🌐 Community

RHS 250×100×6.3 - Section Properties

The RHS 250×100×6.3 is a rectangular hollow section with a mass of 33 kg/m, an overall depth of 250 mm and width of 100 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 42.1 cm², a second moment of area Iᵧ of 3210 cm⁴, a plastic modulus Wₚₗ,ᵧ of 326 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
33 kg/m
Depth
250 mm
Width
100 mm
Wall thickness
6.3 mm
Area
42.1 cm²
Ask about capacity, buckling or detailing for RHS 250×100×6.3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Hot-finished section profile showing the dimension symbols used for RHS 250×100×6.3

Dimension symbols for RHS Hot-finished sections. Not to scale.

RHS 250×100×6.3 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh250
Width of sectionb100
Wall thicknesst6.3

Mass and area

Mass per metremass33
Cross-sectional areaA42.1

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy3210
Elastic section modulus about y-axisWel,y257
Plastic section modulus about y-axisWpl,y326
Radius of gyration about y-axisiy8.73

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz751
Elastic section modulus about z-axisWel,z150
Plastic section modulus about z-axisWpl,z169
Radius of gyration about z-axisiz4.22

Torsion and warping

Torsion constant (St Venant)It1980
Section modulus for torsionWt264

Classification and stability

Flange local-buckling ratiocf/tf12.9
Web local-buckling ratiocw/tw36.7

Surface area

Surface area per metreSA/m0.684
Surface area per tonneSA/t20.7m²/t

Is RHS 250×100×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending28%
32.8 / 115.7 kNm
Shear4%
26.3 / 616.3 kN
Deflection61%
8.5 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 250×100×6.3

RHS 250×100×6.3 has a mass of 33 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 396 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 250×100×6.3 has a depth of 250 mm, a width of 100 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 42.1 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 326 cm³, and the elastic modulus Wel,y is 257 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 116 kNm before any stability check.

The second moment of area about the major axis, Iy, is 3,210 cm⁴, and about the minor axis Iz is 751 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 12.9 for the flange and cw/tw = 36.7 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.73 cm about the major axis and iz is 4.22 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.22 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 1,980 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Hot-finished sizes

RHS 220×120×12.5RHS 220×120×14.2RHS 220×120×16RHS 250×100×5RHS 250×100×7.1RHS 250×100×8RHS 250×100×8.8RHS 250×100×10

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF RHS 250×150×5vs RHS 250×150×5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Hot-finished sizes
Rectangular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…