CivilAxisCivilAxis
☕ Support🌐 Community

RHS 260×140×8.8 - Section Properties

The RHS 260×140×8.8 is a rectangular hollow section with a mass of 52.2 kg/m, an overall depth of 260 mm and width of 140 mm and a wall thickness of 8.8 mm. It has a cross-sectional area of 66.5 cm², a second moment of area Iᵧ of 5830 cm⁴, a plastic modulus Wₚₗ,ᵧ of 557 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
52.2 kg/m
Depth
260 mm
Width
140 mm
Wall thickness
8.8 mm
Area
66.5 cm²
Ask about capacity, buckling or detailing for RHS 260×140×8.8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Hot-finished section profile showing the dimension symbols used for RHS 260×140×8.8

Dimension symbols for RHS Hot-finished sections. Not to scale.

RHS 260×140×8.8 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh260
Width of sectionb140
Wall thicknesst8.8

Mass and area

Mass per metremass52.2
Cross-sectional areaA66.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy5830
Elastic section modulus about y-axisWel,y449
Plastic section modulus about y-axisWpl,y557
Radius of gyration about y-axisiy9.37

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz2200
Elastic section modulus about z-axisWel,z314
Plastic section modulus about z-axisWpl,z360
Radius of gyration about z-axisiz5.75

Torsion and warping

Torsion constant (St Venant)It5110
Section modulus for torsionWt527

Classification and stability

Flange local-buckling ratiocf/tf12.9
Web local-buckling ratiocw/tw26.5

Surface area

Surface area per metreSA/m0.777
Surface area per tonneSA/t14.9m²/t

Is RHS 260×140×8.8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending31%
60.9 / 197.7 kNm
Shear6%
48.8 / 885.9 kN
Deflection62%
8.6 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about RHS 260×140×8.8

RHS 260×140×8.8 has a mass of 52.2 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 626 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 260×140×8.8 has a depth of 260 mm, a width of 140 mm, a wall thickness of 8.8 mm, with a cross-sectional area of 66.5 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 557 cm³, and the elastic modulus Wel,y is 449 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 198 kNm before any stability check.

The second moment of area about the major axis, Iy, is 5,830 cm⁴, and about the minor axis Iz is 2,200 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 12.9 for the flange and cw/tw = 26.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 9.37 cm about the major axis and iz is 5.75 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.75 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5,110 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Hot-finished sizes

RHS 260×140×5RHS 260×140×6.3RHS 260×140×7.1RHS 260×140×8RHS 260×140×10RHS 260×140×12.5RHS 260×140×14.2RHS 260×140×16

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Hot-finished sizes
Rectangular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…