CivilAxisCivilAxis
☕ Support🌐 Community

RHS 300×250×5 - Section Properties

The RHS 300×250×5 is a rectangular hollow section with a mass of 42.2 kg/m, an overall depth of 300 mm and width of 250 mm and a wall thickness of 5 mm. It has a cross-sectional area of 53.7 cm², a second moment of area Iᵧ of 7410 cm⁴, a plastic modulus Wₚₗ,ᵧ of 575 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
42.2 kg/m
Depth
300 mm
Width
250 mm
Wall thickness
5 mm
Area
53.7 cm²
Ask about capacity, buckling or detailing for RHS 300×250×5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
RHS Hot-finished section profile showing the dimension symbols used for RHS 300×250×5

Dimension symbols for RHS Hot-finished sections. Not to scale.

RHS 300×250×5 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh300
Width of sectionb250
Wall thicknesst5

Mass and area

Mass per metremass42.2
Cross-sectional areaA53.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7410
Elastic section modulus about y-axisWel,y494
Plastic section modulus about y-axisWpl,y575
Radius of gyration about y-axisiy11.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz5610
Elastic section modulus about z-axisWel,z449
Plastic section modulus about z-axisWpl,z508
Radius of gyration about z-axisiz10.2

Torsion and warping

Torsion constant (St Venant)It9770
Section modulus for torsionWt697

Classification and stability

Flange local-buckling ratiocf/tf47
Web local-buckling ratiocw/tw57

Surface area

Surface area per metreSA/m1.09
Surface area per tonneSA/t25.8m²/t

Common questions about RHS 300×250×5

RHS 300×250×5 has a mass of 42.2 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 506 kg, which is the figure to use for a steel take-off or when checking a lift.

RHS 300×250×5 has a depth of 300 mm, a width of 250 mm, a wall thickness of 5 mm, with a cross-sectional area of 53.7 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 575 cm³, and the elastic modulus Wel,y is 494 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 204 kNm before any stability check.

The second moment of area about the major axis, Iy, is 7,410 cm⁴, and about the minor axis Iz is 5,610 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 47 for the flange and cw/tw = 57 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 11.7 cm about the major axis and iz is 10.2 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.2 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 9,770 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related RHS Hot-finished sizes

RHS 300×200×10RHS 300×200×12.5RHS 300×200×14.2RHS 300×200×16RHS 300×250×6.3RHS 300×250×7.1RHS 300×250×8RHS 300×250×8.8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF RHS 300×200×6vs RHS 300×200×6vs RHS 300×200×6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All RHS Hot-finished sizes
Rectangular Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…