SHS 250×250×8 - Section Properties
The SHS 250×250×8 is a square hollow section with a mass of 60.3 kg/m, an overall depth of 250 mm and width of 250 mm and a wall thickness of 8 mm. It has a cross-sectional area of 76.8 cm², a second moment of area Iᵧ of 7460 cm⁴, a plastic modulus Wₚₗ,ᵧ of 694 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).
Ask about capacity, buckling or detailing for SHS 250×250×8.
or pick a unit on any row

Dimension symbols for SHS Hot-finished sections. Not to scale.
Is SHS 250×250×8 strong enough?
Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.
✅Passes - 60% utilised, deflection governs
Bending30%
75.0 / 246.4 kNmShear8%
60.0 / 787.0 kNDeflection60%
8.3 / 13.9 mmClass 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.
Common questions about SHS 250×250×8
Related SHS Hot-finished sizes
Compare with other sections
Side-by-side properties against the closest equivalent in each catalogue.
Learn more
Rate thisNo ratings yet
Sign in to join the discussion.