CivilAxisCivilAxis
☕ Support🌐 Community

SHS 250×250×8 - Section Properties

The SHS 250×250×8 is a square hollow section with a mass of 60.3 kg/m, an overall depth of 250 mm and width of 250 mm and a wall thickness of 8 mm. It has a cross-sectional area of 76.8 cm², a second moment of area Iᵧ of 7460 cm⁴, a plastic modulus Wₚₗ,ᵧ of 694 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
60.3 kg/m
Depth
250 mm
Width
250 mm
Wall thickness
8 mm
Area
76.8 cm²
Ask about capacity, buckling or detailing for SHS 250×250×8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 250×250×8

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 250×250×8 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh250
Width of sectionb250
Wall thicknesst8

Mass and area

Mass per metremass60.3
Cross-sectional areaA76.8

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy7460
Elastic section modulus about y-axisWel,y596
Plastic section modulus about y-axisWpl,y694
Radius of gyration about y-axisiy9.86

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz7460
Elastic section modulus about z-axisWel,z596
Plastic section modulus about z-axisWpl,z694
Radius of gyration about z-axisiz9.86

Torsion and warping

Torsion constant (St Venant)It11500
Section modulus for torsionWt880

Surface area

Surface area per metreSA/m0.979
Surface area per tonneSA/t16.3m²/t

Is SHS 250×250×8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
75.0 / 246.4 kNm
Shear8%
60.0 / 787.0 kN
Deflection60%
8.3 / 13.9 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 250×250×8

SHS 250×250×8 has a mass of 60.3 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 724 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 250×250×8 has a depth of 250 mm, a width of 250 mm, a wall thickness of 8 mm, with a cross-sectional area of 76.8 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 694 cm³, and the elastic modulus Wel,y is 596 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 246 kNm before any stability check.

The second moment of area about the major axis, Iy, is 7,460 cm⁴, and about the minor axis Iz is 7,460 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 9.86 cm about the major axis and iz is 9.86 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.86 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 11,500 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 200×200×16SHS 250×250×5SHS 250×250×6.3SHS 250×250×7.1SHS 250×250×8.8SHS 250×250×10SHS 250×250×12.5SHS 250×250×14.2

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 250×250×8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…