CivilAxisCivilAxis
☕ Support🌐 Community

SHS 300×300×12.5 - Section Properties

The SHS 300×300×12.5 is a square hollow section with a mass of 112 kg/m, an overall depth of 300 mm and width of 300 mm and a wall thickness of 12.5 mm. It has a cross-sectional area of 142 cm², a second moment of area Iᵧ of 19400 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1530 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
112 kg/m
Depth
300 mm
Width
300 mm
Wall thickness
12.5 mm
Area
142 cm²
Ask about capacity, buckling or detailing for SHS 300×300×12.5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 300×300×12.5

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 300×300×12.5 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh300
Width of sectionb300
Wall thicknesst12.5

Mass and area

Mass per metremass112
Cross-sectional areaA142

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy19400
Elastic section modulus about y-axisWel,y1300
Plastic section modulus about y-axisWpl,y1530
Radius of gyration about y-axisiy11.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz19400
Elastic section modulus about z-axisWel,z1300
Plastic section modulus about z-axisWpl,z1530
Radius of gyration about z-axisiz11.7

Torsion and warping

Torsion constant (St Venant)It30300
Section modulus for torsionWt1900

Surface area

Surface area per metreSA/m1.17
Surface area per tonneSA/t10.5m²/t

Is SHS 300×300×12.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
162.0 / 543.1 kNm
Shear7%
108.0 / 1455.2 kN
Deflection60%
9.9 / 16.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 300×300×12.5

SHS 300×300×12.5 has a mass of 112 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 1344 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 300×300×12.5 has a depth of 300 mm, a width of 300 mm, a wall thickness of 12.5 mm, with a cross-sectional area of 142 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,530 cm³, and the elastic modulus Wel,y is 1,300 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 543 kNm before any stability check.

The second moment of area about the major axis, Iy, is 19,400 cm⁴, and about the minor axis Iz is 19,400 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 11.7 cm about the major axis and iz is 11.7 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 11.7 cm a 1.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 30,300 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 300×300×7.1SHS 300×300×8SHS 300×300×8.8SHS 300×300×10SHS 300×300×14.2SHS 300×300×16SHS 350×350×8SHS 350×350×8.8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 300×300×12.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section