SHS 80×80×10 - Section Properties

The SHS 80×80×10 is a square hollow section with a mass of 21.1 kg/m, an overall depth of 80 mm and width of 80 mm and a wall thickness of 10 mm. It has a cross-sectional area of 26.9 cm², a second moment of area Iᵧ of 214 cm⁴, a plastic modulus Wₚₗ,ᵧ of 69.3 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
21.1 kg/m
Depth
80 mm
Width
80 mm
Wall thickness
10 mm
Area
26.9 cm²
Ask about capacity, buckling or detailing for SHS 80×80×10.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 80×80×10

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 80×80×10 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh80
Width of sectionb80
Wall thicknesst10

Mass and area

Mass per metremass21.1
Cross-sectional areaA26.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy214
Elastic section modulus about y-axisWel,y53.5
Plastic section modulus about y-axisWpl,y69.3
Radius of gyration about y-axisiy2.82

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz214
Elastic section modulus about z-axisWel,z53.5
Plastic section modulus about z-axisWpl,z69.3
Radius of gyration about z-axisiz2.82

Torsion and warping

Torsion constant (St Venant)It360
Section modulus for torsionWt76.8

Surface area

Surface area per metreSA/m0.294
Surface area per tonneSA/t13.9m²/t

Is SHS 80×80×10 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending29%
7.2 / 24.6 kNm
Shear7%
19.1 / 275.7 kN
Deflection60%
2.5 / 4.2 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 80×80×10

SHS 80×80×10 has a mass of 21.1 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 253 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 80×80×10 has a depth of 80 mm, a width of 80 mm, a wall thickness of 10 mm, with a cross-sectional area of 26.9 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 69.3 cm³, and the elastic modulus Wel,y is 53.5 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 25 kNm before any stability check.

The second moment of area about the major axis, Iy, is 214 cm⁴, and about the minor axis Iz is 214 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 2.82 cm about the major axis and iz is 2.82 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.82 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 360 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 80×80×6.3SHS 80×80×7.1SHS 80×80×8SHS 80×80×8.8SHS 80×80×12.5SHS 90×90×3.6SHS 90×90×4SHS 90×90×5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section