SHS 90×90×6.3 - Section Properties

The SHS 90×90×6.3 is a square hollow section with a mass of 16.2 kg/m, an overall depth of 90 mm and width of 90 mm and a wall thickness of 6.3 mm. It has a cross-sectional area of 20.7 cm², a second moment of area Iᵧ of 238 cm⁴, a plastic modulus Wₚₗ,ᵧ of 64.3 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
16.2 kg/m
Depth
90 mm
Width
90 mm
Wall thickness
6.3 mm
Area
20.7 cm²
Ask about capacity, buckling or detailing for SHS 90×90×6.3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 90×90×6.3

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 90×90×6.3 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh90
Width of sectionb90
Wall thicknesst6.3

Mass and area

Mass per metremass16.2
Cross-sectional areaA20.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy238
Elastic section modulus about y-axisWel,y53
Plastic section modulus about y-axisWpl,y64.3
Radius of gyration about y-axisiy3.4

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz238
Elastic section modulus about z-axisWel,z53
Plastic section modulus about z-axisWpl,z64.3
Radius of gyration about z-axisiz3.4

Torsion and warping

Torsion constant (St Venant)It382
Section modulus for torsionWt77

Surface area

Surface area per metreSA/m0.344
Surface area per tonneSA/t21.2m²/t

Is SHS 90×90×6.3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending26%
6.0 / 22.8 kNm
Shear6%
12.0 / 212.1 kN
Deflection60%
3.3 / 5.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 90×90×6.3

SHS 90×90×6.3 has a mass of 16.2 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 194 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 90×90×6.3 has a depth of 90 mm, a width of 90 mm, a wall thickness of 6.3 mm, with a cross-sectional area of 20.7 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 64.3 cm³, and the elastic modulus Wel,y is 53 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 23 kNm before any stability check.

The second moment of area about the major axis, Iy, is 238 cm⁴, and about the minor axis Iz is 238 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 3.4 cm about the major axis and iz is 3.4 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.4 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 382 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 80×80×12.5SHS 90×90×3.6SHS 90×90×4SHS 90×90×5SHS 90×90×7.1SHS 90×90×8SHS 90×90×8.8SHS 90×90×10

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…