CivilAxisCivilAxis
☕ Support🌐 Community

TFC 180x75x7 - Section Properties

The TFC 180x75x7 is a tapered flange channel with a mass of 21.4 kg/m. It has a cross-sectional area of 27.2 cm², a second moment of area Iᵧ of 1380 cm⁴, an elastic modulus Wₑₗ,ᵧ of 154 cm³, tabulated by CivilAxis from Continental Steel.

Mass
21.4 kg/m
Area
27.2 cm²
Ask about capacity, buckling or detailing for TFC 180x75x7.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
Tapered Channel section profile showing the dimension symbols used for TFC 180x75x7

Dimension symbols for Tapered Channel sections. Not to scale.

TFC 180x75x7 section properties to Continental Steel.

Geometry

Web thicknesstw7
Flange thicknesstf10.5
Root fillet radiusr11
Toe radiusr25.5

Mass and area

Mass per metremass21.4
Cross-sectional areaA27.2

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1380
Elastic section modulus about y-axisWel,y154
Radius of gyration about y-axisiy7.12

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz137
Elastic section modulus about z-axisWel,z25.5
Radius of gyration about z-axisiz2.24

Detailing dimensions

Centroid distance from back of leg (y)cy2.15

Common questions about TFC 180x75x7

TFC 180x75x7 has a mass of 21.4 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 257 kg, which is the figure to use for a steel take-off or when checking a lift.

The elastic section modulus about the major axis, Wel,y, is 154 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 1,380 cm⁴, and about the minor axis Iz is 137 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.12 cm about the major axis and iz is 2.24 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.24 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related Tapered Channel sizes

TFC 100x50x5TFC 125x65x6TFC 150x75x6.5TFC 150x75x9TFC 180x90x7.5TFC 200x80x7.5TFC 200x90x8TFC 230x80x8

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)