UB 254×146×31 - Section Properties

The UB 254×146×31 is a universal beam with a mass of 31.1 kg/m, an overall depth of 251.4 mm and width of 146.1 mm. It has a cross-sectional area of 39.7 cm², a second moment of area Iᵧ of 4410 cm⁴, a plastic modulus Wₚₗ,ᵧ of 393 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
31.1 kg/m
Depth
251.4 mm
Width
146.1 mm
Area
39.7 cm²
Ask about capacity, buckling or detailing for UB 254×146×31.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 254×146×31

Dimension symbols for UB sections. Not to scale.

UB 254×146×31 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh251.4
Width of sectionb146.1
Web thicknesstw6
Flange thicknesstf8.6
Root fillet radiusr7.6
Depth between filletsd219

Mass and area

Mass per metremass31.1
Cross-sectional areaA39.7

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4410
Elastic section modulus about y-axisWel,y351
Plastic section modulus about y-axisWpl,y393
Radius of gyration about y-axisiy10.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz448
Elastic section modulus about z-axisWel,z61.3
Plastic section modulus about z-axisWpl,z94.1
Radius of gyration about z-axisiz3.36

Torsion and warping

Torsion constant (St Venant)It8.55
Warping constantIw0.066

Classification and stability

Flange local-buckling ratiocf/tf7.26
Web local-buckling ratiocw/tw36.5
Buckling parameteru0.879
Torsional indexX29.6

Detailing dimensions

End clearanceC5
Notch dimension NN82
Notch dimension nn18

Surface area

Surface area per metreSA/m1.06
Surface area per tonneSA/t34m²/t

Is UB 254×146×31 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending32%
44.5 / 139.5 kNm
Shear11%
35.6 / 336.0 kN
Deflection60%
8.3 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 254×146×31

UB 254×146×31 has a mass of 31.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 373 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 254×146×31 has a depth of 251.4 mm, a width of 146.1 mm, a web thickness of 6 mm, a flange thickness of 8.6 mm, with a cross-sectional area of 39.7 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 393 cm³, and the elastic modulus Wel,y is 351 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 140 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,410 cm⁴, and about the minor axis Iz is 448 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.26 for the flange and cw/tw = 36.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.5 cm about the major axis and iz is 3.36 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.36 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 8.55 cm⁴, and the warping constant Iw is 0.066 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 305×102×28UB 305×102×25UB 254×146×43UB 254×146×37UB 254×102×28UB 254×102×25UB 254×102×22UB 203×133×30

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…