CivilAxisCivilAxis
☕ Support🌐 Community

UB 254×102×22 - Section Properties

The UB 254×102×22 is a universal beam with a mass of 22 kg/m, an overall depth of 254 mm and width of 101.6 mm. It has a cross-sectional area of 28 cm², a second moment of area Iᵧ of 2840 cm⁴, a plastic modulus Wₚₗ,ᵧ of 259 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
22 kg/m
Depth
254 mm
Width
101.6 mm
Area
28 cm²
Ask about capacity, buckling or detailing for UB 254×102×22.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 254×102×22

Dimension symbols for UB sections. Not to scale.

UB 254×102×22 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh254
Width of sectionb101.6
Web thicknesstw5.7
Flange thicknesstf6.8
Root fillet radiusr7.6
Depth between filletsd225.2

Mass and area

Mass per metremass22
Cross-sectional areaA28

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2840
Elastic section modulus about y-axisWel,y224
Plastic section modulus about y-axisWpl,y259
Radius of gyration about y-axisiy10.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz119
Elastic section modulus about z-axisWel,z23.5
Plastic section modulus about z-axisWpl,z37.3
Radius of gyration about z-axisiz2.06

Torsion and warping

Torsion constant (St Venant)It4.15
Warping constantIw0.0182

Classification and stability

Flange local-buckling ratiocf/tf5.93
Web local-buckling ratiocw/tw39.5
Buckling parameteru0.856
Torsional indexX36.3

Detailing dimensions

End clearanceC5
Notch dimension NN58
Notch dimension nn16

Surface area

Surface area per metreSA/m0.89
Surface area per tonneSA/t40.5m²/t

Is UB 254×102×22 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
28.1 / 91.9 kNm
Shear7%
22.5 / 319.8 kN
Deflection59%
8.2 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 254×102×22

UB 254×102×22 has a mass of 22 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 264 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 254×102×22 has a depth of 254 mm, a width of 101.6 mm, a web thickness of 5.7 mm, a flange thickness of 6.8 mm, with a cross-sectional area of 28 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 259 cm³, and the elastic modulus Wel,y is 224 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 92 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,840 cm⁴, and about the minor axis Iz is 119 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.93 for the flange and cw/tw = 39.5 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 10.1 cm about the major axis and iz is 2.06 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.06 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4.15 cm⁴, and the warping constant Iw is 0.0182 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 254×146×37UB 254×146×31UB 254×102×28UB 254×102×25UB 203×133×30UB 203×133×25UB 203×102×23UB 178×102×19

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 10X15

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…