UB 178×102×19 - Section Properties

The UB 178×102×19 is a universal beam with a mass of 19 kg/m, an overall depth of 177.8 mm and width of 101.2 mm. It has a cross-sectional area of 24.3 cm², a second moment of area Iᵧ of 1360 cm⁴, a plastic modulus Wₚₗ,ᵧ of 171 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
19 kg/m
Depth
177.8 mm
Width
101.2 mm
Area
24.3 cm²
Ask about capacity, buckling or detailing for UB 178×102×19.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 178×102×19

Dimension symbols for UB sections. Not to scale.

UB 178×102×19 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh177.8
Width of sectionb101.2
Web thicknesstw4.8
Flange thicknesstf7.9
Root fillet radiusr7.6
Depth between filletsd146.8

Mass and area

Mass per metremass19
Cross-sectional areaA24.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1360
Elastic section modulus about y-axisWel,y153
Plastic section modulus about y-axisWpl,y171
Radius of gyration about y-axisiy7.48

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz137
Elastic section modulus about z-axisWel,z27
Plastic section modulus about z-axisWpl,z41.6
Radius of gyration about z-axisiz2.37

Torsion and warping

Torsion constant (St Venant)It4.41
Warping constantIw0.0099

Classification and stability

Flange local-buckling ratiocf/tf5.14
Web local-buckling ratiocw/tw30.6
Buckling parameteru0.886
Torsional indexX22.6

Detailing dimensions

End clearanceC4
Notch dimension NN60
Notch dimension nn16

Surface area

Surface area per metreSA/m0.738
Surface area per tonneSA/t38.7m²/t

Is UB 178×102×19 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending32%
19.5 / 60.7 kNm
Shear11%
22.3 / 202.7 kN
Deflection60%
5.8 / 9.7 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 178×102×19

UB 178×102×19 has a mass of 19 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 228 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 178×102×19 has a depth of 177.8 mm, a width of 101.2 mm, a web thickness of 4.8 mm, a flange thickness of 7.9 mm, with a cross-sectional area of 24.3 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 171 cm³, and the elastic modulus Wel,y is 153 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 61 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,360 cm⁴, and about the minor axis Iz is 137 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.14 for the flange and cw/tw = 30.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 7.48 cm about the major axis and iz is 2.37 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.37 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 4.41 cm⁴, and the warping constant Iw is 0.0099 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 254×102×28UB 254×102×25UB 254×102×22UB 203×133×30UB 203×133×25UB 203×102×23UB 152×89×16UB 127×76×13

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 180

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…