CivilAxisCivilAxis
☕ Support🌐 Community

UB 152×89×16 - Section Properties

The UB 152×89×16 is a universal beam with a mass of 16 kg/m, an overall depth of 152.4 mm and width of 88.7 mm. It has a cross-sectional area of 20.3 cm², a second moment of area Iᵧ of 834 cm⁴, a plastic modulus Wₚₗ,ᵧ of 123 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
16 kg/m
Depth
152.4 mm
Width
88.7 mm
Area
20.3 cm²
Ask about capacity, buckling or detailing for UB 152×89×16.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 152×89×16

Dimension symbols for UB sections. Not to scale.

UB 152×89×16 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh152.4
Width of sectionb88.7
Web thicknesstw4.5
Flange thicknesstf7.7
Root fillet radiusr7.6
Depth between filletsd121.8

Mass and area

Mass per metremass16
Cross-sectional areaA20.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy834
Elastic section modulus about y-axisWel,y109
Plastic section modulus about y-axisWpl,y123
Radius of gyration about y-axisiy6.41

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz89.8
Elastic section modulus about z-axisWel,z20.2
Plastic section modulus about z-axisWpl,z31.2
Radius of gyration about z-axisiz2.1

Torsion and warping

Torsion constant (St Venant)It3.56
Warping constantIw0.0047

Classification and stability

Flange local-buckling ratiocf/tf4.48
Web local-buckling ratiocw/tw27.1
Buckling parameteru0.89
Torsional indexX19.5

Detailing dimensions

End clearanceC4
Notch dimension NN54
Notch dimension nn16

Surface area

Surface area per metreSA/m0.638
Surface area per tonneSA/t40m²/t

Is UB 152×89×16 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
14.3 / 43.7 kNm
Shear11%
19.1 / 167.2 kN
Deflection61%
5.1 / 8.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 152×89×16

UB 152×89×16 has a mass of 16 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 192 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 152×89×16 has a depth of 152.4 mm, a width of 88.7 mm, a web thickness of 4.5 mm, a flange thickness of 7.7 mm, with a cross-sectional area of 20.3 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 123 cm³, and the elastic modulus Wel,y is 109 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 44 kNm before any stability check.

The second moment of area about the major axis, Iy, is 834 cm⁴, and about the minor axis Iz is 89.8 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.48 for the flange and cw/tw = 27.1 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 6.41 cm about the major axis and iz is 2.1 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.1 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 3.56 cm⁴, and the warping constant Iw is 0.0047 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 254×102×28UB 254×102×25UB 254×102×22UB 203×133×30UB 203×133×25UB 203×102×23UB 178×102×19UB 127×76×13

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 160

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…