CivilAxisCivilAxis
☕ Support🌐 Community

UB 203×133×25 - Section Properties

The UB 203×133×25 is a universal beam with a mass of 25.1 kg/m, an overall depth of 203.2 mm and width of 133.2 mm. It has a cross-sectional area of 32 cm², a second moment of area Iᵧ of 2340 cm⁴, a plastic modulus Wₚₗ,ᵧ of 258 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
25.1 kg/m
Depth
203.2 mm
Width
133.2 mm
Area
32 cm²
Ask about capacity, buckling or detailing for UB 203×133×25.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 203×133×25

Dimension symbols for UB sections. Not to scale.

UB 203×133×25 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh203.2
Width of sectionb133.2
Web thicknesstw5.7
Flange thicknesstf7.8
Root fillet radiusr7.6
Depth between filletsd172.4

Mass and area

Mass per metremass25.1
Cross-sectional areaA32

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2340
Elastic section modulus about y-axisWel,y230
Plastic section modulus about y-axisWpl,y258
Radius of gyration about y-axisiy8.56

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz308
Elastic section modulus about z-axisWel,z46.2
Plastic section modulus about z-axisWpl,z70.9
Radius of gyration about z-axisiz3.1

Torsion and warping

Torsion constant (St Venant)It5.96
Warping constantIw0.0294

Classification and stability

Flange local-buckling ratiocf/tf7.2
Web local-buckling ratiocw/tw30.2
Buckling parameteru0.876
Torsional indexX25.6

Detailing dimensions

End clearanceC5
Notch dimension NN74
Notch dimension nn16

Surface area

Surface area per metreSA/m0.915
Surface area per tonneSA/t36.5m²/t

Is UB 203×133×25 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
30.0 / 91.6 kNm
Shear11%
30.0 / 263.4 kN
Deflection61%
6.8 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 203×133×25

UB 203×133×25 has a mass of 25.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 301 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 203×133×25 has a depth of 203.2 mm, a width of 133.2 mm, a web thickness of 5.7 mm, a flange thickness of 7.8 mm, with a cross-sectional area of 32 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 258 cm³, and the elastic modulus Wel,y is 230 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 92 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,340 cm⁴, and about the minor axis Iz is 308 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.2 for the flange and cw/tw = 30.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.56 cm about the major axis and iz is 3.1 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 3.1 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 5.96 cm⁴, and the warping constant Iw is 0.0294 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 254×102×28UB 254×102×25UB 254×102×22UB 203×133×30UB 203×102×23UB 178×102×19UB 152×89×16UB 127×76×13

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE O 200vs S 8X18.4

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.