CivilAxisCivilAxis
☕ Support🌐 Community

UB 203×102×23 - Section Properties

The UB 203×102×23 is a universal beam with a mass of 23.1 kg/m, an overall depth of 203.2 mm and width of 101.8 mm. It has a cross-sectional area of 29.4 cm², a second moment of area Iᵧ of 2100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 234 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
23.1 kg/m
Depth
203.2 mm
Width
101.8 mm
Area
29.4 cm²
Ask about capacity, buckling or detailing for UB 203×102×23.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 203×102×23

Dimension symbols for UB sections. Not to scale.

UB 203×102×23 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh203.2
Width of sectionb101.8
Web thicknesstw5.4
Flange thicknesstf9.3
Root fillet radiusr7.6
Depth between filletsd169.4

Mass and area

Mass per metremass23.1
Cross-sectional areaA29.4

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy2100
Elastic section modulus about y-axisWel,y207
Plastic section modulus about y-axisWpl,y234
Radius of gyration about y-axisiy8.46

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz164
Elastic section modulus about z-axisWel,z32.2
Plastic section modulus about z-axisWpl,z49.7
Radius of gyration about z-axisiz2.36

Torsion and warping

Torsion constant (St Venant)It7.02
Warping constantIw0.0154

Classification and stability

Flange local-buckling ratiocf/tf4.37
Web local-buckling ratiocw/tw31.4
Buckling parameteru0.888
Torsional indexX22.4

Detailing dimensions

End clearanceC5
Notch dimension NN60
Notch dimension nn18

Surface area

Surface area per metreSA/m0.79
Surface area per tonneSA/t34.2m²/t

Is UB 203×102×23 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending33%
27.0 / 83.1 kNm
Shear11%
27.0 / 253.8 kN
Deflection61%
6.8 / 11.1 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 203×102×23

UB 203×102×23 has a mass of 23.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 277 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 203×102×23 has a depth of 203.2 mm, a width of 101.8 mm, a web thickness of 5.4 mm, a flange thickness of 9.3 mm, with a cross-sectional area of 29.4 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 234 cm³, and the elastic modulus Wel,y is 207 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 83 kNm before any stability check.

The second moment of area about the major axis, Iy, is 2,100 cm⁴, and about the minor axis Iz is 164 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.37 for the flange and cw/tw = 31.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 8.46 cm about the major axis and iz is 2.36 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.36 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 7.02 cm⁴, and the warping constant Iw is 0.0154 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 254×102×28UB 254×102×25UB 254×102×22UB 203×133×30UB 203×133×25UB 178×102×19UB 152×89×16UB 127×76×13

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE AA 220vs W 8X15

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…