CivilAxisCivilAxis
☕ Support🌐 Community

UB 406×178×74 - Section Properties

The UB 406×178×74 is a universal beam with a mass of 74.2 kg/m, an overall depth of 412.8 mm and width of 179.5 mm. It has a cross-sectional area of 94.5 cm², a second moment of area Iᵧ of 27300 cm⁴, a plastic modulus Wₚₗ,ᵧ of 1500 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
74.2 kg/m
Depth
412.8 mm
Width
179.5 mm
Area
94.5 cm²
Ask about capacity, buckling or detailing for UB 406×178×74.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 406×178×74

Dimension symbols for UB sections. Not to scale.

UB 406×178×74 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh412.8
Width of sectionb179.5
Web thicknesstw9.5
Flange thicknesstf16
Root fillet radiusr10.2
Depth between filletsd360.4

Mass and area

Mass per metremass74.2
Cross-sectional areaA94.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy27300
Elastic section modulus about y-axisWel,y1320
Plastic section modulus about y-axisWpl,y1500
Radius of gyration about y-axisiy17

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1550
Elastic section modulus about z-axisWel,z172
Plastic section modulus about z-axisWpl,z267
Radius of gyration about z-axisiz4.04

Torsion and warping

Torsion constant (St Venant)It62.8
Warping constantIw0.608

Classification and stability

Flange local-buckling ratiocf/tf4.68
Web local-buckling ratiocw/tw37.9
Buckling parameteru0.882
Torsional indexX27.5

Detailing dimensions

End clearanceC7
Notch dimension NN96
Notch dimension nn28

Surface area

Surface area per metreSA/m1.51
Surface area per tonneSA/t20.4m²/t

Is UB 406×178×74 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
162.6 / 532.5 kNm
Shear9%
76.5 / 857.6 kN
Deflection60%
14.2 / 23.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 406×178×74

UB 406×178×74 has a mass of 74.2 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 890 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 406×178×74 has a depth of 412.8 mm, a width of 179.5 mm, a web thickness of 9.5 mm, a flange thickness of 16 mm, with a cross-sectional area of 94.5 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 1,500 cm³, and the elastic modulus Wel,y is 1,320 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 533 kNm before any stability check.

The second moment of area about the major axis, Iy, is 27,300 cm⁴, and about the minor axis Iz is 1,550 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.68 for the flange and cw/tw = 37.9 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 17 cm about the major axis and iz is 4.04 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.04 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 62.8 cm⁴, and the warping constant Iw is 0.608 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 457×152×67UB 457×152×60UB 457×152×52UB 406×178×85UB 406×178×67UB 406×178×60UB 406×178×54UB 406×140×53

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE O 400vs W 16X50vs H-400x200x9x15

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…