CivilAxisCivilAxis
☕ Support🌐 Community

UJ 89×89×19 - Section Properties

The UJ 89×89×19 is a universal joist with a mass of 19.5 kg/m, an overall depth of 88.9 mm and width of 88.9 mm. It has a cross-sectional area of 24.9 cm², a second moment of area Iᵧ of 307 cm⁴, a plastic modulus Wₚₗ,ᵧ of 82.7 cm³, tabulated by CivilAxis from BS 4-1:2005 (SCI P363 Blue Book).

Mass
19.5 kg/m
Depth
88.9 mm
Width
88.9 mm
Area
24.9 cm²
Ask about capacity, buckling or detailing for UJ 89×89×19.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UJ section profile showing the dimension symbols used for UJ 89×89×19

Dimension symbols for UJ sections. Not to scale.

UJ 89×89×19 section properties to BS 4-1:2005.

Geometry

Depth of sectionh88.9
Width of sectionb88.9
Web thicknesstw9.5
Flange thicknesstf9.9
Root fillet radiusr11.1
Toe radiusr23.2
Depth between filletsd44.2

Mass and area

Mass per metremass19.5
Cross-sectional areaA24.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy307
Elastic section modulus about y-axisWel,y69
Plastic section modulus about y-axisWpl,y82.7
Radius of gyration about y-axisiy3.51

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz101
Elastic section modulus about z-axisWel,z22.8
Plastic section modulus about z-axisWpl,z38
Radius of gyration about z-axisiz2.02

Torsion and warping

Torsion constant (St Venant)It11.5
Warping constantIw0.00158

Classification and stability

Flange local-buckling ratiocf/tf2.89
Web local-buckling ratiocw/tw4.65
Buckling parameteru0.829
Torsional indexX6.6

Detailing dimensions

End clearanceC7
Notch dimension NN46
Notch dimension nn24

Surface area

Surface area per metreSA/m0.476
Surface area per tonneSA/t24.4m²/t

Is UJ 89×89×19 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending26%
7.5 / 29.4 kNm
Shear7%
15.0 / 213.9 kN
Deflection58%
3.2 / 5.6 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UJ 89×89×19

UJ 89×89×19 has a mass of 19.5 kg/m, tabulated to BS 4-1:2005. A 12 m length therefore weighs about 234 kg, which is the figure to use for a steel take-off or when checking a lift.

UJ 89×89×19 has a depth of 88.9 mm, a width of 88.9 mm, a web thickness of 9.5 mm, a flange thickness of 9.9 mm, with a cross-sectional area of 24.9 cm². These are the nominal dimensions from BS 4-1:2005; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 82.7 cm³, and the elastic modulus Wel,y is 69 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 29 kNm before any stability check.

The second moment of area about the major axis, Iy, is 307 cm⁴, and about the minor axis Iz is 101 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 2.89 for the flange and cw/tw = 4.65 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 3.51 cm about the major axis and iz is 2.02 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.02 cm a 0.2 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 11.5 cm⁴, and the warping constant Iw is 0.00158 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UJ sizes

UJ 127×114×29UJ 127×114×27UJ 127×76×16UJ 114×114×27UJ 102×102×23UJ 102×44×7UJ 76×76×15UJ 76×76×13

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UJ sizes
Universal Joists (UJ)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…