CivilAxisCivilAxis
☕ Support🌐 Community

UPN 260 - Section Properties

The UPN 260 is a European taper-flange channel (UPN) with a mass of 37.9 kg/m, an overall depth of 260 mm and width of 90 mm. It has a cross-sectional area of 48.3 cm², a second moment of area Iᵧ of 4820 cm⁴, an elastic modulus Wₑₗ,ᵧ of 371 cm³, tabulated by CivilAxis from Continental Steel.

Mass
37.9 kg/m
Depth
260 mm
Width
90 mm
Area
48.3 cm²
Ask about capacity, buckling or detailing for UPN 260.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UPN section profile showing the dimension symbols used for UPN 260

Dimension symbols for UPN sections. Not to scale.

UPN 260 section properties to Continental Steel.

Geometry

Depth of sectionh260
Width of sectionb90
Web thicknesstw10
Flange thicknesstf14
Root fillet radiusr14
Toe radiusr27

Mass and area

Mass per metremass37.9
Cross-sectional areaA48.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4820
Elastic section modulus about y-axisWel,y371
Radius of gyration about y-axisiy9.99

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz317
Elastic section modulus about z-axisWel,z48
Radius of gyration about z-axisiz2.56

Detailing dimensions

Centroid distance from back of leg (y)cy2.8

Common questions about UPN 260

UPN 260 has a mass of 37.9 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 455 kg, which is the figure to use for a steel take-off or when checking a lift.

UPN 260 has a depth of 260 mm, a width of 90 mm, a web thickness of 10 mm, a flange thickness of 14 mm, with a cross-sectional area of 48.3 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The elastic section modulus about the major axis, Wel,y, is 371 cm³. Use it with M_el,Rd = Wel,y x f_y / gamma_M0 for an elastic check.

The second moment of area about the major axis, Iy, is 4,820 cm⁴, and about the minor axis Iz is 317 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 9.99 cm about the major axis and iz is 2.56 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 2.56 cm a 0.3 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

Related UPN sizes

UPN 180UPN 200UPN 220UPN 240UPN 280UPN 300UPN 320UPN 350

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)
All UPN sizes
Taper-Flange Channels (UPN)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…