The theory behind the calculator: how a pile carries load through its shaft and tip, how each method turns a borehole log into unit friction and end bearing, how negative skin friction is located and treated, and how TCVN 10304, Eurocode 7 and a factor of safety turn an ultimate capacity into a verdict.
Run this method in the free calculator and export the result to Excel (.xlsx) or PDF.
How a pile carries axial load
A compression pile carries its load in two ways: by shaft friction along its sides and by end bearing under its tip. The ultimate geotechnical capacity is the sum of the two, each integrated over the part of the pile that develops it.
The two components do not mobilise together. Shaft friction is fully developed after about 5-10 mm of relative movement, almost independent of the pile size; end bearing needs a settlement of around 10% of the base diameter. At working load a pile therefore carries most of its load in friction, and EN 1997-1 7.6.1.1(3) takes a settlement of 10% of the base diameter as the failure criterion where a load test shows no clear plunge.
The calculation is set up the way a hand calculation is checked. The shaft is cut at every layer boundary, at the water table and at the neutral plane, and each segment is evaluated at its mid-depth. With a constant unit weight per layer the vertical effective stress is linear inside a segment, so its mid-depth value is exactly the average. Where a property varies strongly within a thick layer, split the layer.
SPT methods
TCVN 10304 Appendix G.3.2 - the Japanese formula
The formula TCVN 10304 attributes to the Architectural Institute of Japan (1988) is the most widely used SPT method in Vietnam. It treats granular and cohesive layers differently and sums them along the shaft:
Both factors come from Semple & Rigden (1984), plotted on log-log axes. The adhesion factor is 1.0 up to and 0.5 from 0.8, varying log-linearly between; the length factor is 1.0 up to L/d = 50 and 0.7 from 120. The base resistance depends on the soil at the tip:
| Tip in | Driven / jacked | Bored |
|---|---|---|
| Granular soil | ||
| Cohesive soil |
is the mean SPT value from 4 diameters above to 1 diameter below the tip, also capped at 50 in sand. The calculator averages it depth-weighted across any layer boundary inside the window and warns when the borehole log stops before the window does.
TCVN 10304 Appendix G.3.1 - Meyerhof (1976)
Meyerhof's relations for granular soil are the older and simpler pair:
The note under G.8 sends cohesive layers in a mixed profile to the alpha relations, so the calculator uses formula G.11 for them, as in G.3.2. Meyerhof gives no rule for a tip in clay, and the G.3.2 rule ( driven, bored) is used there - the Details tab says so.
Singapore CP 4 - the SPT rule
SS CP 4:2003 clause 7.5.3(b) relates both components directly to N for every soil type, which suits the residual soils and Old Alluvium of Singapore that do not divide neatly into clay and sand:
| Pile | Ks | f limit | Kb | qb limit |
|---|---|---|---|---|
| Bored | 1.5-2.5 (residual soils), 2-3 (Old Alluvium) | 150 kPa (300 kPa in Old Alluvium) | 1-3 | 10 MPa |
| Driven | 2-5 | 200 kPa | 6-9 | 18 MPa |
CP 4 has been superseded by SS EN 1997-1, but these coefficients remain the local calculation model; used under Eurocode 7 they need the model factor of the Singapore National Annex.
Which N - the energy and overburden corrections
The blow count depends on the energy the hammer actually delivers. Most SPT design correlations were developed with hammers of about 60% efficiency, so the field value is always first brought to that reference (Skempton 1986; Coduto et al. 2016, 4.11):
In sand the blow count also rises with confining stress, so a soil-property correlation normalises it to one atmosphere. The calculator uses the FHWA form, capped so that ; clay gets no overburden correction:
The energy correction is always appropriate. The overburden correction depends on how the method was built: it is always used where N becomes a soil property - the friction angle , fitted to frozen (undisturbed) sand samples, or Peck, Hanson & Thornburn - but the direct SPT pile formulas above were fitted to N without it, so applying it there is an option, off by default.
Hollow and open-ended piles
Spun piles, pipe piles and hollow precast piles carry shaft friction on the outside surface only. A closed toe bears on the full section. An open toe first cuts into the ground and bears only on the ring of pile material; once the soil inside jams and moves down with the pile it forms a plug and the toe behaves like a closed one. Following Paikowsky & Whitman as given by Coduto et al. (2016, sec. 13), the plug is taken to form at a penetration-to-diameter ratio above 20 in clay and 35 in sand - the upper ends of the published ranges.
Static method from soil strength
Cohesive soil - the alpha method
Loading is fast compared with drainage in clay, so the shaft friction is a fraction of the undrained strength - a total-stress analysis. For driven piles the adhesion factor of Randolph & Murphy (1985) depends on how overconsolidated the clay is, expressed through :
With this is the API RP 2A form; Ξ± is limited to 1.0. For bored piles the calculator uses Reese & O'Neill (1989) as modified by Brown et al. (2010): Ξ± = 0.55 for up to 1.5, falling linearly to 0.45 at 2.5, zero within the top 1.5 m (shrinkage and seasonal moisture), and a unit friction of at most 260 kPa. The base in clay is , with for most deep foundations.
Granular soil - the beta method
Sand drains as fast as it is loaded, so friction depends on the horizontal effective stress on the shaft and the interface friction angle. The beta method lumps both into one factor:
Kβ follows Mayne & Kulhawy (1982). The two ratios capture installation and the interface, after Kulhawy (1991); the calculator offers the tabulated ranges and defaults to their cautious lower bound:
| Installation | K/Kβ |
|---|---|
| Jetted pile | 0.5-0.7 |
| Driven, small displacement | 0.7-1.2 |
| Driven, large displacement | 1.0-2.0 |
| Bored, dry, prompt concreting | 0.9-1.0 |
| Bored, slurry, good workmanship | 0.9-1.0 |
| Bored, slurry, fair workmanship | 0.6-0.7 |
| Bored, casing below the water table | 0.7-0.9 |
| Pile-soil interface | Ξ΄/Οβ² |
|---|---|
| Rough concrete (cast in place) | 1.0 |
| Smooth concrete (precast) | 0.8-1.0 |
| Rough steel | 0.7-0.9 |
| Smooth steel (pipe, H-pile) | 0.5-0.7 |
| Timber | 0.8-0.9 |
| Bored with slurry | 0.8-1.0 |
The base in sand is . By default comes from TCVN 10304 Table G.1 (after AS 2159), which also holds constant below a limiting depth - the field observation that base resistance stops growing with depth:
| Relative density | ZL/d | Nβ²q driven | Nβ²q bored |
|---|---|---|---|
| Loose (0.2-0.4) | 6 | 60 | 25 |
| Medium dense (0.4-0.75) | 8 | 100 | 60 |
| Dense (0.75-0.9) | 15 | 180 | 100 |
A manual Ξ± or Ξ² on any layer overrides the relation - the way to enter a value back-analysed from a load test - and optional limits on and reproduce practice such as API RP 2A's.
Negative skin friction
Where soft soil is still consolidating - under new fill, or as groundwater is drawn down - it settles more than the pile and drags it down. The depth at which pile and soil settle equally is the neutral plane: above it friction acts downwards as a load, below it the shaft resists as usual, and the axial force in the pile peaks there. The calculator places it at a fraction of the settling depth (SS CP 4 7.3.6: for friction piles, for end-bearing piles; field data ).
The three codes write the same physics in different places:
Ξ· scales the drag load: 1.0 for full mobilisation; TCVN 10304 takes 40% of the friction for fill 2-5 m high. CP 4 deducts the drag after the factor of safety, so a drag load costs the allowable load one-for-one - the reason it so often governs.
Verification
TCVN 10304 clause 7.1.11
| Case | Piles | Ξ³k (by calculation) | Ξ³k (static load test) |
|---|---|---|---|
| (a) low cap on good soil, end-bearing piles | any | 1.4 | 1.2 |
| (a) single pile under a column, > 600 kN driven or > 2500 kN bored | 1 | 1.6 | 1.4 |
| (b) high cap, compressible layer, friction piles, all tension piles | 21 or more | 1.40 | 1.25 |
| 11-20 | 1.55 | 1.4 | |
| 6-10 | 1.65 | 1.5 | |
| 1-5 | 1.75 | 1.6 |
For tension, with (0.6 for a penetration under 4 m), clauses 7.2.2.3 and 7.2.3.4, checked the same way with case (b).
Global factor of safety - SS CP 4 7.3.8
The split form, recommended for large bored piles, recognises that the shaft and base mobilise at different settlements; where both are checked, the smaller allowable load governs.
Eurocode 7 - Design Approach 1
Combination 1 (A1 + M1 + R1) factors the actions; Combination 2 (A2 + M1 + R4) factors the resistances. The characteristic resistance comes either from correlation factors ΞΎ on the number of test profiles (the model-pile procedure, 7.6.2.3(5)) or from a model factor on the calculated resistance (the alternative procedure, 7.6.2.3(8)).
| Set | Pile | Ξ³b | Ξ³s | Ξ³s,t |
|---|---|---|---|---|
| R4 - EN recommended | Driven | 1.3 | 1.3 | 1.6 |
| R4 - EN recommended | Bored | 1.6 | 1.3 | 1.6 |
| R4 - EN recommended | CFA | 1.45 | 1.3 | 1.6 |
| R4 - Singapore NA | Driven | 1.7 (1.5) | 1.5 (1.3) | 2.0 (1.7) |
| R4 - Singapore NA | Bored / CFA | 2.0 (1.7) | 1.6 (1.4) | 2.0 (1.7) |
Bracketed Singapore values apply when serviceability is explicitly verified. The correlation factor for one profile is 1.40 (EN) or 1.55 (Singapore); the Singapore model factor is 1.55, or 1.35 when verified by a maintained load test to the unfactored ultimate resistance.
What these methods do not cover
- SPT correlations carry real scatter - between methods, 30-50% is normal. Codes ask for load tests because of it.
- Settlement is a separate serviceability check; a pile with enough capacity can still settle too much.
- Group effects (block failure, interaction) and piles socketed into rock are outside this calculation.
- The structural capacity of the pile section must be checked separately.
References
- TCVN 10304:2014. "MΓ³ng cα»c - TiΓͺu chuαΊ©n thiαΊΏt kαΊΏ (Pile foundation - Design standard)." Ministry of Science and Technology, Vietnam. Clauses 7.1.11, 7.2.2.3, 7.2.5 and Appendix G.
- EN 1997-1:2004+A1:2013. "Eurocode 7: Geotechnical design - Part 1: General rules." Clause 7.6 and Annex A (Tables A.3, A.6-A.10).
- NA+A1:2018 to SS EN 1997-1:2010. "Singapore National Annex to Eurocode 7: Geotechnical design - Part 1." Enterprise Singapore. A.3.3.2 and Tables A.NA.6-A.NA.10.
- SS CP 4:2003. "Code of practice for foundations." SPRING Singapore. Section 7: Pile foundations (7.3.6, 7.3.8, 7.5.3).
- Meyerhof, G.G. (1976). "Bearing Capacity and Settlement of Pile Foundations." ASCE Journal of the Geotechnical Engineering Division, 102(GT3), 197-228.
- Randolph, M.F. & Murphy, B.S. (1985). "Shaft Capacity of Driven Piles in Clay." Offshore Technology Conference, Houston.
- Reese, L.C. & O'Neill, M.W. (1989). "New Design Method for Drilled Shafts from Common Soil and Rock Tests." Foundation Engineering: Current Principles and Practices, ASCE, 1026-1039.
- Brown, D.A., Turner, J.P. & Castelli, R.J. (2010). "Drilled Shafts: Construction Procedures and LRFD Design Methods." FHWA Geotechnical Engineering Circular No. 10, FHWA NHI-10-016.
- Kulhawy, F.H. (1991). "Drilled Shaft Foundations." Chapter 14 in Foundation Engineering Handbook, 2nd ed., Van Nostrand Reinhold.
- Mayne, P.W. & Kulhawy, F.H. (1982). "K0-OCR Relationships in Soil." ASCE Journal of the Geotechnical Engineering Division, 108(GT6), 851-872.
- Peck, R.B., Hanson, W.E. & Thornburn, T.H. (1974). Foundation Engineering, 2nd ed. John Wiley, New York.
- Skempton, A.W. (1986). "Standard Penetration Test Procedures and the Effects in Sands of Overburden Pressure, Relative Density, Particle Size, Ageing and Overconsolidation." Geotechnique, 36(3), 425-447.
- Coduto, D.P., Kitch, W.A. & Yeung, M.R. (2016). Foundation Design: Principles and Practices, 3rd ed. Pearson, Chapters 15-16.
Frequently asked questions
Ready to size a pile? Enter your borehole log and get the shaft friction by layer, the end bearing, the drag load and the shortest pile that passes your check.
πͺ¨Open the interactive pile bearing capacity calculatorβ