TiαΊΏng Việt

Pile Bearing Capacity - Theory

The theory behind the calculator: how a pile carries load through its shaft and tip, how each method turns a borehole log into unit friction and end bearing, how negative skin friction is located and treated, and how TCVN 10304, Eurocode 7 and a factor of safety turn an ultimate capacity into a verdict.

πŸͺ¨Open the interactive pile bearing capacity calculatorβ†’

Run this method in the free calculator and export the result to Excel (.xlsx) or PDF.

How a pile carries axial load

A compression pile carries its load in two ways: by shaft friction along its sides and by end bearing under its tip. The ultimate geotechnical capacity is the sum of the two, each integrated over the part of the pile that develops it.

Qu=Qs+Qb=uβˆ‘fi li+qb AbQ_u = Q_s + Q_b = u \sum f_i\, l_i + q_b\, A_b
where:
uu
perimeter of the pile cross-section (m)
fif_i
unit shaft friction in segment i (kPa)
lil_i
length of segment i (m)
qbq_b
unit base resistance (kPa)
AbA_b
area of the pile base (mΒ²)

The two components do not mobilise together. Shaft friction is fully developed after about 5-10 mm of relative movement, almost independent of the pile size; end bearing needs a settlement of around 10% of the base diameter. At working load a pile therefore carries most of its load in friction, and EN 1997-1 7.6.1.1(3) takes a settlement of 10% of the base diameter as the failure criterion where a load test shows no clear plunge.

The calculation is set up the way a hand calculation is checked. The shaft is cut at every layer boundary, at the water table and at the neutral plane, and each segment is evaluated at its mid-depth. With a constant unit weight per layer the vertical effective stress is linear inside a segment, so its mid-depth value is exactly the average. Where a property varies strongly within a thick layer, split the layer.

Οƒvβ€²(z)=βˆ‘Ξ³j hjβˆ’Ξ³w (zβˆ’zw)\sigma'_v(z) = \sum \gamma_j\, h_j - \gamma_w\, (z - z_w)

SPT methods

TCVN 10304 Appendix G.3.2 - the Japanese formula

The formula TCVN 10304 attributes to the Architectural Institute of Japan (1988) is the most widely used SPT method in Vietnam. It treats granular and cohesive layers differently and sums them along the shaft:

Rc,u=qbAb+uβˆ‘(fc,i lc,i+fs,i ls,i)R_{c,u} = q_b A_b + u \sum \left( f_{c,i}\, l_{c,i} + f_{s,i}\, l_{s,i} \right)
fs,i=10 Ns,i3fc,i=Ξ±p fL cu,if_{s,i} = \frac{10\, N_{s,i}}{3} \qquad f_{c,i} = \alpha_p\, f_L\, c_{u,i}
where:
Ns,iN_{s,i}
mean SPT N in granular layer i (taken at most 50 in sand)
cu,ic_{u,i}
undrained shear strength of cohesive layer i; without a strength test, cα΅€ = 6.25 N (kPa)
Ξ±p\alpha_p
adhesion factor from Fig. G.2a against cα΅€/Οƒβ€²α΅₯
fLf_L
length factor from Fig. G.2b against L/d; 1.0 for bored piles

Both factors come from Semple & Rigden (1984), plotted on log-log axes. The adhesion factor is 1.0 up to cu/Οƒvβ€²=0.35c_u/\sigma'_v = 0.35 and 0.5 from 0.8, varying log-linearly between; the length factor is 1.0 up to L/d = 50 and 0.7 from 120. The base resistance depends on the soil at the tip:

Tip inDriven / jackedBored
Granular soilqb=300 Npq_b = 300\, N_pqb=150 Npq_b = 150\, N_p
Cohesive soilqb=9 cuq_b = 9\, c_uqb=6 cuq_b = 6\, c_u

NpN_p is the mean SPT value from 4 diameters above to 1 diameter below the tip, also capped at 50 in sand. The calculator averages it depth-weighted across any layer boundary inside the window and warns when the borehole log stops before the window does.

TCVN 10304 Appendix G.3.1 - Meyerhof (1976)

Meyerhof's relations for granular soil are the older and simpler pair:

qb=k1Npfi=k2Ns,iq_b = k_1 N_p \qquad f_i = k_2 N_{s,i}
where:
k1k_1
40 h/d, at most 400, for driven piles (h = penetration depth); 120 for bored piles
k2k_2
2.0 for driven piles, 1.0 for bored piles
NpN_p
mean SPT N from 1 diameter above to 4 diameters below the tip

The note under G.8 sends cohesive layers in a mixed profile to the alpha relations, so the calculator uses formula G.11 for them, as in G.3.2. Meyerhof gives no rule for a tip in clay, and the G.3.2 rule (9 cu9\,c_u driven, 6 cu6\,c_u bored) is used there - the Details tab says so.

Singapore CP 4 - the SPT rule

SS CP 4:2003 clause 7.5.3(b) relates both components directly to N for every soil type, which suits the residual soils and Old Alluvium of Singapore that do not divide neatly into clay and sand:

f=Ks Nqb=Kb (40 N)f = K_s\, N \qquad q_b = K_b\, (40\, N)
PileKsf limitKbqb limit
Bored1.5-2.5 (residual soils), 2-3 (Old Alluvium)150 kPa (300 kPa in Old Alluvium)1-310 MPa
Driven2-5200 kPa6-918 MPa

CP 4 has been superseded by SS EN 1997-1, but these coefficients remain the local calculation model; used under Eurocode 7 they need the model factor of the Singapore National Annex.

Which N - the energy and overburden corrections

The blow count depends on the energy the hammer actually delivers. Most SPT design correlations were developed with hammers of about 60% efficiency, so the field value is always first brought to that reference (Skempton 1986; Coduto et al. 2016, 4.11):

N60=N ER60N_{60} = N \, \frac{ER}{60}

In sand the blow count also rises with confining stress, so a soil-property correlation normalises it to one atmosphere. The calculator uses the FHWA form, capped so that (N1)60≀2 N60(N_1)_{60} \le 2\, N_{60}; clay gets no overburden correction:

(N1)60=CNN60,CN=95.76Οƒv′≀2.0(N_1)_{60} = C_N N_{60}, \qquad C_N = \sqrt{\frac{95.76}{\sigma'_v}} \le 2.0

The energy correction is always appropriate. The overburden correction depends on how the method was built: it is always used where N becomes a soil property - the friction angle Ο†β€²=15.4 (N1)60+20∘\varphi' = \sqrt{15.4\,(N_1)_{60}} + 20^\circ, fitted to frozen (undisturbed) sand samples, or Peck, Hanson & Thornburn - but the direct SPT pile formulas above were fitted to N without it, so applying it there is an option, off by default.

Hollow and open-ended piles

Spun piles, pipe piles and hollow precast piles carry shaft friction on the outside surface only. A closed toe bears on the full section. An open toe first cuts into the ground and bears only on the ring of pile material; once the soil inside jams and moves down with the pile it forms a plug and the toe behaves like a closed one. Following Paikowsky & Whitman as given by Coduto et al. (2016, sec. 13), the plug is taken to form at a penetration-to-diameter ratio above 20 in clay and 35 in sand - the upper ends of the published ranges.

Static method from soil strength

Cohesive soil - the alpha method

Loading is fast compared with drainage in clay, so the shaft friction is a fraction of the undrained strength - a total-stress analysis. For driven piles the adhesion factor of Randolph & Murphy (1985) depends on how overconsolidated the clay is, expressed through cu/Οƒvβ€²c_u/\sigma'_v:

Ξ±=(cuΟƒvβ€²)NC0.5(cuΟƒvβ€²)βˆ’0.5Β forΒ cuΟƒv′≀1,Ξ±=(cuΟƒvβ€²)NC0.5(cuΟƒvβ€²)βˆ’0.25Β forΒ cuΟƒvβ€²>1\alpha = \left(\frac{c_u}{\sigma'_v}\right)_{NC}^{0.5} \left(\frac{c_u}{\sigma'_v}\right)^{-0.5} \ \text{for}\ \frac{c_u}{\sigma'_v} \le 1, \qquad \alpha = \left(\frac{c_u}{\sigma'_v}\right)_{NC}^{0.5} \left(\frac{c_u}{\sigma'_v}\right)^{-0.25} \ \text{for}\ \frac{c_u}{\sigma'_v} > 1

With (cu/Οƒvβ€²)NC=0.25(c_u/\sigma'_v)_{NC} = 0.25this is the API RP 2A form; Ξ± is limited to 1.0. For bored piles the calculator uses Reese & O'Neill (1989) as modified by Brown et al. (2010): Ξ± = 0.55 for cu/pac_u/p_a up to 1.5, falling linearly to 0.45 at 2.5, zero within the top 1.5 m (shrinkage and seasonal moisture), and a unit friction of at most 260 kPa. The base in clay is qb=Nc cuq_b = N_c\, c_u, with Nc=9N_c = 9 for most deep foundations.

Granular soil - the beta method

Sand drains as fast as it is loaded, so friction depends on the horizontal effective stress on the shaft and the interface friction angle. The beta method lumps both into one factor:

f=β σvβ€²,Ξ²=K0(KK0)tan⁑ ⁣(δφ′ φ′),K0=(1βˆ’sin⁑φ′) OCRsin⁑φ′f = \beta\, \sigma'_v, \qquad \beta = K_0 \left(\frac{K}{K_0}\right) \tan\!\left(\frac{\delta}{\varphi'}\, \varphi'\right), \qquad K_0 = (1 - \sin\varphi')\, \mathrm{OCR}^{\sin\varphi'}

Kβ‚€ follows Mayne & Kulhawy (1982). The two ratios capture installation and the interface, after Kulhawy (1991); the calculator offers the tabulated ranges and defaults to their cautious lower bound:

InstallationK/Kβ‚€
Jetted pile0.5-0.7
Driven, small displacement0.7-1.2
Driven, large displacement1.0-2.0
Bored, dry, prompt concreting0.9-1.0
Bored, slurry, good workmanship0.9-1.0
Bored, slurry, fair workmanship0.6-0.7
Bored, casing below the water table0.7-0.9
Pile-soil interfaceΞ΄/Ο†β€²
Rough concrete (cast in place)1.0
Smooth concrete (precast)0.8-1.0
Rough steel0.7-0.9
Smooth steel (pipe, H-pile)0.5-0.7
Timber0.8-0.9
Bored with slurry0.8-1.0

The base in sand is qb=Nq σvβ€²q_b = N_q\, \sigma'_v. By default NqN_q comes from TCVN 10304 Table G.1 (after AS 2159), which also holds Οƒvβ€²\sigma'_v constant below a limiting depth ZLZ_L - the field observation that base resistance stops growing with depth:

Relative densityZL/dNβ€²q drivenNβ€²q bored
Loose (0.2-0.4)66025
Medium dense (0.4-0.75)810060
Dense (0.75-0.9)15180100

A manual Ξ± or Ξ² on any layer overrides the relation - the way to enter a value back-analysed from a load test - and optional limits on ff and qbq_breproduce practice such as API RP 2A's.

Negative skin friction

Where soft soil is still consolidating - under new fill, or as groundwater is drawn down - it settles more than the pile and drags it down. The depth at which pile and soil settle equally is the neutral plane: above it friction acts downwards as a load, below it the shaft resists as usual, and the axial force in the pile peaks there. The calculator places it at a fraction of the settling depth LsL_s (SS CP 4 7.3.6: 0.6 Ls0.6\,L_s for friction piles, 1.0 Ls1.0\,L_s for end-bearing piles; field data 0.7-1.0 Ls0.7\text{-}1.0\,L_s).

The three codes write the same physics in different places:

TCVNΒ 10304Β (7.2.5.2):Rc,u=Qb+Qspβˆ’Ξ·β€‰Qsn\text{TCVN 10304 (7.2.5.2):}\quad R_{c,u} = Q_b + Q_{sp} - \eta\, Q_{sn}
CPΒ 4Β (7.3.6):Qa,L=Qb+QspFLβˆ’Ξ·β€‰Qsnβ‰₯P\text{CP 4 (7.3.6):}\quad Q_{a,L} = \frac{Q_b + Q_{sp}}{F_L} - \eta\, Q_{sn} \ge P
ENΒ 1997-1Β (7.3.2.2):Fc,d=Ξ³G (Gk+η Qsn)+Ξ³Q Qk≀Rc,d(Qb,Qsp)\text{EN 1997-1 (7.3.2.2):}\quad F_{c,d} = \gamma_G\, (G_k + \eta\, Q_{sn}) + \gamma_Q\, Q_k \le R_{c,d}(Q_{b,} Q_{sp})

Ξ· scales the drag load: 1.0 for full mobilisation; TCVN 10304 takes 40% of the friction for fill 2-5 m high. CP 4 deducts the drag after the factor of safety, so a drag load costs the allowable load one-for-one - the reason it so often governs.

Verification

TCVN 10304 clause 7.1.11

Nc,d≀γ0Ξ³n Rc,d,Rc,d=Rc,kΞ³kN_{c,d} \le \frac{\gamma_0}{\gamma_n}\, R_{c,d}, \qquad R_{c,d} = \frac{R_{c,k}}{\gamma_k}
where:
Nc,dN_{c,d}
factored design compression on the pile
Ξ³0\gamma_0
working-condition factor: 1.0 for a single pile, 1.15 in a multi-pile foundation
Ξ³n\gamma_n
importance factor: 1.2, 1.15, 1.1 for class I, II, III
Ξ³k\gamma_k
ground reliability factor, from the table below
Rc,kR_{c,k}
characteristic capacity; with fewer than six values, the smallest (7.1.12)
CasePilesΞ³k (by calculation)Ξ³k (static load test)
(a) low cap on good soil, end-bearing pilesany1.41.2
(a) single pile under a column, > 600 kN driven or > 2500 kN bored11.61.4
(b) high cap, compressible layer, friction piles, all tension piles21 or more1.401.25
11-201.551.4
6-101.651.5
1-51.751.6

For tension, Rt,u=Ξ³c uβˆ‘fi liR_{t,u} = \gamma_c\, u \sum f_i\, l_i with Ξ³c=0.8\gamma_c = 0.8 (0.6 for a penetration under 4 m), clauses 7.2.2.3 and 7.2.3.4, checked the same way with case (b).

Global factor of safety - SS CP 4 7.3.8

Qa=Qs+Qbβˆ’WF(F=2-3),Qa=QsFs+QbFb(Fs=1.5-2,Β Fb=3)Q_a = \frac{Q_s + Q_b - W}{F} \quad (F = 2\text{-}3), \qquad Q_a = \frac{Q_s}{F_s} + \frac{Q_b}{F_b} \quad (F_s = 1.5\text{-}2,\ F_b = 3)

The split form, recommended for large bored piles, recognises that the shaft and base mobilise at different settlements; where both are checked, the smaller allowable load governs.

Eurocode 7 - Design Approach 1

Combination 1 (A1 + M1 + R1) factors the actions; Combination 2 (A2 + M1 + R4) factors the resistances. The characteristic resistance comes either from correlation factors ΞΎ on the number of test profiles (the model-pile procedure, 7.6.2.3(5)) or from a model factor on the calculated resistance (the alternative procedure, 7.6.2.3(8)).

Rc,d=Rb,kΞ³b+Rs,kΞ³s,Rk=RcalΞΎΒ orΒ RcalΞ³RdR_{c,d} = \frac{R_{b,k}}{\gamma_b} + \frac{R_{s,k}}{\gamma_s}, \qquad R_{k} = \frac{R_{cal}}{\xi}\ \text{or}\ \frac{R_{cal}}{\gamma_{Rd}}
SetPileΞ³bΞ³sΞ³s,t
R4 - EN recommendedDriven1.31.31.6
R4 - EN recommendedBored1.61.31.6
R4 - EN recommendedCFA1.451.31.6
R4 - Singapore NADriven1.7 (1.5)1.5 (1.3)2.0 (1.7)
R4 - Singapore NABored / CFA2.0 (1.7)1.6 (1.4)2.0 (1.7)

Bracketed Singapore values apply when serviceability is explicitly verified. The correlation factor for one profile is 1.40 (EN) or 1.55 (Singapore); the Singapore model factor is 1.55, or 1.35 when verified by a maintained load test to the unfactored ultimate resistance.

What these methods do not cover

  • SPT correlations carry real scatter - between methods, 30-50% is normal. Codes ask for load tests because of it.
  • Settlement is a separate serviceability check; a pile with enough capacity can still settle too much.
  • Group effects (block failure, interaction) and piles socketed into rock are outside this calculation.
  • The structural capacity of the pile section must be checked separately.

References

  • TCVN 10304:2014. "MΓ³ng cọc - TiΓͺu chuαΊ©n thiαΊΏt kαΊΏ (Pile foundation - Design standard)." Ministry of Science and Technology, Vietnam. Clauses 7.1.11, 7.2.2.3, 7.2.5 and Appendix G.
  • EN 1997-1:2004+A1:2013. "Eurocode 7: Geotechnical design - Part 1: General rules." Clause 7.6 and Annex A (Tables A.3, A.6-A.10).
  • NA+A1:2018 to SS EN 1997-1:2010. "Singapore National Annex to Eurocode 7: Geotechnical design - Part 1." Enterprise Singapore. A.3.3.2 and Tables A.NA.6-A.NA.10.
  • SS CP 4:2003. "Code of practice for foundations." SPRING Singapore. Section 7: Pile foundations (7.3.6, 7.3.8, 7.5.3).
  • Meyerhof, G.G. (1976). "Bearing Capacity and Settlement of Pile Foundations." ASCE Journal of the Geotechnical Engineering Division, 102(GT3), 197-228.
  • Randolph, M.F. & Murphy, B.S. (1985). "Shaft Capacity of Driven Piles in Clay." Offshore Technology Conference, Houston.
  • Reese, L.C. & O'Neill, M.W. (1989). "New Design Method for Drilled Shafts from Common Soil and Rock Tests." Foundation Engineering: Current Principles and Practices, ASCE, 1026-1039.
  • Brown, D.A., Turner, J.P. & Castelli, R.J. (2010). "Drilled Shafts: Construction Procedures and LRFD Design Methods." FHWA Geotechnical Engineering Circular No. 10, FHWA NHI-10-016.
  • Kulhawy, F.H. (1991). "Drilled Shaft Foundations." Chapter 14 in Foundation Engineering Handbook, 2nd ed., Van Nostrand Reinhold.
  • Mayne, P.W. & Kulhawy, F.H. (1982). "K0-OCR Relationships in Soil." ASCE Journal of the Geotechnical Engineering Division, 108(GT6), 851-872.
  • Peck, R.B., Hanson, W.E. & Thornburn, T.H. (1974). Foundation Engineering, 2nd ed. John Wiley, New York.
  • Skempton, A.W. (1986). "Standard Penetration Test Procedures and the Effects in Sands of Overburden Pressure, Relative Density, Particle Size, Ageing and Overconsolidation." Geotechnique, 36(3), 425-447.
  • Coduto, D.P., Kitch, W.A. & Yeung, M.R. (2016). Foundation Design: Principles and Practices, 3rd ed. Pearson, Chapters 15-16.

Frequently asked questions

Shaft friction (skin friction) is the shear resistance mobilised between the side of the pile and the soil around it; end bearing (tip or base resistance) is the bearing capacity of the soil under the tip. They mobilise at very different settlements: shaft friction is usually fully developed after 5-10 mm of movement whatever the pile size, while end bearing needs a settlement of around 10% of the base diameter. That is why a pile at working load carries most of its load in friction, and why some codes put a larger factor on the base.

The depth where the pile and the surrounding soil settle by the same amount. Above it the soil settles more than the pile and drags it down (negative skin friction); below it the pile settles more than the soil and the friction resists the load. The neutral plane is also where the axial force in the pile is greatest. Field data place it at roughly 0.7 to 1.0 times the depth of the settling layer; SS CP 4 suggests 0.6 for friction piles in a uniform consolidating stratum and 1.0 for end-bearing piles.

Because at ultimate load the pile plunges and moves down relative to all the soil, so the friction above the neutral plane reverses and resists like the rest of the shaft. Negative skin friction is a serviceability-period effect: it is a load the pile carries in the long term. EC7 therefore treats the drag load as a permanent action and resists it with the shaft below the neutral plane only, while TCVN 10304 writes the same idea into the resistance with a negative sign.

Loading a pile in clay is fast compared with the time the clay takes to drain, so the relevant strength is the undrained shear strength cu, and the shaft friction is a fraction alpha of it - a total-stress analysis. Sand drains as fast as it is loaded, so friction depends on the effective horizontal stress against the shaft times the tangent of the interface friction angle - an effective-stress analysis, which the beta method lumps into one factor times the vertical effective stress.

Because each was fitted to a different picture of the failure zone around the base. TCVN 10304 G.3.2 (after the Architectural Institute of Japan) averages from 4 diameters above to 1 diameter below the tip; Meyerhof (G.3.1) averages from 1 diameter above to 4 diameters below. Both say the same thing: the base resistance depends on a bulb of soil, not on the single SPT value at the tip level, so a thin weak layer just below the tip matters.

They convert a calculated resistance into a characteristic one, allowing for how much ground data the calculation rests on and how variable it is. With one borehole profile the factor is 1.40 in the EN recommended values (1.55 in the Singapore National Annex); with ten profiles it drops to 1.25 or less. More investigation earns a smaller factor, which is the code's way of paying for site investigation.

Ready to size a pile? Enter your borehole log and get the shaft friction by layer, the end bearing, the drag load and the shortest pile that passes your check.

πŸͺ¨Open the interactive pile bearing capacity calculatorβ†’
Rate this
No ratings yet
Sign in to join the discussion.
Loading…