Work out the geotechnical axial capacity of a single pile from your borehole log. Enter the soil layers with their SPT N values, choose a method - TCVN 10304 Appendix G (Architectural Institute of Japan or Meyerhof), the Singapore CP4 SPT rule, or the static alpha/beta method - and the tool integrates shaft friction layer by layer, adds the end bearing, deducts negative skin friction above the neutral plane, and checks the result to TCVN 10304, EN 1997-1 Design Approach 1 or a factor of safety. A capacity-against-length curve shows the shortest pile that passes. Free, in your browser, no login.
Free online calculator with step-by-step working and one-click Excel (.xlsx) and PDF export.
This free pile bearing capacity calculator works out the geotechnical axial capacity of a single pile - how much load the ground can carry through the pile shaft and its tip before the pile plunges. You enter the soil profile from a borehole log, the pile and its installation method, and the load; the tool integrates the shaft friction layer by layer, adds the end bearing, and checks the result against the load to the code you choose. It runs in your browser, with no login and no download.
It is a geotechnical check, not a structural one: it tells you whether the soil can support the pile, not whether the concrete or steel section is strong enough. For the section itself use the prestressed spun pile check; for lateral load, the lateral pile analysis; for how a cap shares load between piles, the pile group analysis.
The resistance mobilised along the side of the pile, reported for every layer the pile passes through as a unit friction f in kPa and a force Q = f u l in kN. The shaft is cut at each layer boundary, at the water table and at the neutral plane, so a reviewer can recompute every row by hand. Shaft friction is usually fully mobilised after 5-10 mm of settlement, well before the tip, which is why codes such as CP4 allow a lower factor on it.
The bearing resistance of the soil under the pile tip, qb in kPa times the base area. The SPT methods average N over a window around the tip - TCVN 10304 G.3.2 uses 4 diameters above to 1 diameter below - so a strong layer just below the tip, or a weak one just above it, is felt. The tool shows the exact window it averaged over and warns when the borehole log stops inside it.
The ultimate capacity is the sum of shaft and base. The design (or allowable) capacity is what the selected check leaves after its factors: Rc,d to TCVN 10304, Qa for a factor of safety, or Rc,d for each EC7 combination. Both are drawn against tip depth, together with the load, in the capacity-against-length figure.
Where soft soil settles more than the pile - under new fill, or as groundwater is drawn down - friction above the neutral plane acts downwards and adds load instead of resisting it. Mark the settling layers and the tool places the neutral plane at a fraction of the settling depth (0.7 by default), reports the drag load, and treats it the way each code does: inside the resistance with a negative sign for TCVN 10304, as a load deducted after the factor of safety for CP4, and as a permanent action for EC7.
The tool repeats the whole calculation for pile lengths from 2 m down to the bottom of the borehole log and reports the shortest pile that passes the selected check. That answers the question most capacity calculations are really asking - how long the pile has to be - and shows at a glance whether adding length or changing the pile size is the cheaper fix.
Three of the methods turn SPT blow counts directly into capacity. TCVN 10304 Appendix G.3.2 is the Architectural Institute of Japan (1988) formula: f = 10N/3 in sand, αp fL cu in clay, and qb = 300 Np for driven or 150 Np for bored piles. G.3.1 is Meyerhof (1976), with f = 2N and qb up to 400 N for driven piles. The Singapore CP4 rule takes f = Ks N and qb = Kb (40N) with code limits on both.
The static method uses soil strength instead: total-stress alpha in clay (Randolph & Murphy for driven piles, Reese & O'Neill for bored) and effective-stress beta in sand, with K0, K/K0 and delta/phi from Kulhawy. A manual alpha or beta per layer lets you enter a value back-analysed from a load test.
A 350 mm square precast pile driven through 10 m of soft clay into medium dense sand, with its head 1.5 m below ground under the cap and the water table at 1.5 m. Capacity by the CP4 SPT rule with the cautious ends of its coefficient ranges (Ks = 2, Kb = 6) and a hammer energy ratio of 60%, verified to EN 1997-1 Design Approach 1 with the recommended factors for characteristic loads Gk = 500 kN and Qk = 150 kN.
Checked instead to TCVN 10304 clause 7.1.11 (6-pile cap, class II, γk = 1.4) with a design load of 900 kN, the same pile reaches a utilisation of 0.917. The same profile gives an ultimate capacity of 2069.5 kN by the TCVN Japanese formula, 2031.0 kN by Meyerhof and 1433.7 kN by the static method - a spread that is normal for SPT correlations and the reason codes ask for load tests. With an automatic hammer of 75% energy ratio, N60 = 1.25 N and the CP4 capacity rises to 1716.8 kN. Marking the soft clay as settling puts the neutral plane at 8.4 m and adds a 42.8 kN drag load as a permanent action, taking the EC7 utilisation to 1.009 - just short.