Pile Bearing Capacity Calculator (Geotechnical)

Work out the geotechnical axial capacity of a single pile from your borehole log. Enter the soil layers with their SPT N values, choose a method - TCVN 10304 Appendix G (Architectural Institute of Japan or Meyerhof), the Singapore CP4 SPT rule, or the static alpha/beta method - and the tool integrates shaft friction layer by layer, adds the end bearing, deducts negative skin friction above the neutral plane, and checks the result to TCVN 10304, EN 1997-1 Design Approach 1 or a factor of safety. A capacity-against-length curve shows the shortest pile that passes. Free, in your browser, no login.

Free online calculator with step-by-step working and one-click Excel (.xlsx) and PDF export.

Using this pile bearing capacity calculator

What it calculates

This free pile bearing capacity calculator works out the geotechnical axial capacity of a single pile - how much load the ground can carry through the pile shaft and its tip before the pile plunges. You enter the soil profile from a borehole log, the pile and its installation method, and the load; the tool integrates the shaft friction layer by layer, adds the end bearing, and checks the result against the load to the code you choose. It runs in your browser, with no login and no download.

It is a geotechnical check, not a structural one: it tells you whether the soil can support the pile, not whether the concrete or steel section is strong enough. For the section itself use the prestressed spun pile check; for lateral load, the lateral pile analysis; for how a cap shares load between piles, the pile group analysis.

What you enter

Soil layers
Depth range, description, cohesive or granular, bulk unit weight and the field SPT N value of each layer
Soil strength (optional)
Undrained shear strength cu for clays and friction angle for sands; left blank they are derived from N
Groundwater
Water-table depth (or a dry site) and the unit weight of water
Pile
Circular or square section, diameter or side, embedded length, and the depth of the pile head below ground
Installation
Driven or jacked, bored, or CFA - every method changes its coefficients with this
Settling layers
Mark soft soil still consolidating under fill or drawdown to include negative skin friction
Load
A factored design load (TCVN), a working load (factor of safety) or characteristic actions (EC7)

Shaft friction (skin friction)

The resistance mobilised along the side of the pile, reported for every layer the pile passes through as a unit friction f in kPa and a force Q = f u l in kN. The shaft is cut at each layer boundary, at the water table and at the neutral plane, so a reviewer can recompute every row by hand. Shaft friction is usually fully mobilised after 5-10 mm of settlement, well before the tip, which is why codes such as CP4 allow a lower factor on it.

End bearing (tip resistance)

The bearing resistance of the soil under the pile tip, qb in kPa times the base area. The SPT methods average N over a window around the tip - TCVN 10304 G.3.2 uses 4 diameters above to 1 diameter below - so a strong layer just below the tip, or a weak one just above it, is felt. The tool shows the exact window it averaged over and warns when the borehole log stops inside it.

Ultimate and design capacity

The ultimate capacity is the sum of shaft and base. The design (or allowable) capacity is what the selected check leaves after its factors: Rc,d to TCVN 10304, Qa for a factor of safety, or Rc,d for each EC7 combination. Both are drawn against tip depth, together with the load, in the capacity-against-length figure.

Negative skin friction (drag load)

Where soft soil settles more than the pile - under new fill, or as groundwater is drawn down - friction above the neutral plane acts downwards and adds load instead of resisting it. Mark the settling layers and the tool places the neutral plane at a fraction of the settling depth (0.7 by default), reports the drag load, and treats it the way each code does: inside the resistance with a negative sign for TCVN 10304, as a load deducted after the factor of safety for CP4, and as a permanent action for EC7.

Required pile length

The tool repeats the whole calculation for pile lengths from 2 m down to the bottom of the borehole log and reports the shortest pile that passes the selected check. That answers the question most capacity calculations are really asking - how long the pile has to be - and shows at a glance whether adding length or changing the pile size is the cheaper fix.

SPT methods and the static method

Three of the methods turn SPT blow counts directly into capacity. TCVN 10304 Appendix G.3.2 is the Architectural Institute of Japan (1988) formula: f = 10N/3 in sand, αp fL cu in clay, and qb = 300 Np for driven or 150 Np for bored piles. G.3.1 is Meyerhof (1976), with f = 2N and qb up to 400 N for driven piles. The Singapore CP4 rule takes f = Ks N and qb = Kb (40N) with code limits on both.

The static method uses soil strength instead: total-stress alpha in clay (Randolph & Murphy for driven piles, Reese & O'Neill for bored) and effective-stress beta in sand, with K0, K/K0 and delta/phi from Kulhawy. A manual alpha or beta per layer lets you enter a value back-analysed from a load test.

Worked example (the default inputs)

A 350 mm square precast pile driven through 10 m of soft clay into medium dense sand, with its head 1.5 m below ground under the cap and the water table at 1.5 m. Capacity by the CP4 SPT rule with the cautious ends of its coefficient ranges (Ks = 2, Kb = 6) and a hammer energy ratio of 60%, verified to EN 1997-1 Design Approach 1 with the recommended factors for characteristic loads Gk = 500 kN and Qk = 150 kN.

Pile
350 x 350 mm, driven, 24 m long, tip at 25.5 m
Soft clay 2-12 m (N 2)
f = Ks N = 2 x 2 = 4.0 kPa, Q = 56.0 kN
Stiff sandy clay 12-18 m (N 12)
f = 2 x 12 = 24.0 kPa, Q = 201.6 kN
Medium dense sand 18-25.5 m (N 22)
f = 2 x 22 = 44.0 kPa, Q = 462.0 kN
Shaft resistance
Qs = 726.6 kN (including 7.0 kN in the fill)
End bearing
Np = 22, qb = Kb x 40 Np = 6 x 40 x 22 = 5280 kPa, Qb = 646.8 kN
Ultimate capacity
Rc,u = 1373.4 kN
Characteristic resistance
one profile, ξ = 1.40: Rb,k = 462.0 kN, Rs,k = 519.0 kN
Combination 1 (A1 + M1 + R1)
Fc,d = 1.35 x 500 + 1.5 x 150 = 900.0 kN, Rc,d = 981.0 kN, utilisation 0.917
Combination 2 (A2 + M1 + R4)
Fc,d = 500 + 1.3 x 150 = 695.0 kN, Rc,d = 462.0 / 1.3 + 519.0 / 1.3 = 754.6 kN, utilisation 0.921 - governs, passes
Shortest passing pile
22.7 m at these loads

Checked instead to TCVN 10304 clause 7.1.11 (6-pile cap, class II, γk = 1.4) with a design load of 900 kN, the same pile reaches a utilisation of 0.917. The same profile gives an ultimate capacity of 2069.5 kN by the TCVN Japanese formula, 2031.0 kN by Meyerhof and 1433.7 kN by the static method - a spread that is normal for SPT correlations and the reason codes ask for load tests. With an automatic hammer of 75% energy ratio, N60 = 1.25 N and the CP4 capacity rises to 1716.8 kN. Marking the soft clay as settling puts the neutral plane at 8.4 m and adds a 42.8 kN drag load as a permanent action, taking the EC7 utilisation to 1.009 - just short.

Formulas used

Ultimate capacity (TCVN 10304 G.1)
Rc,u=qbAb+u∑filiR_{c,u} = q_b A_b + u \sum f_i l_i
Sand, JAI (G.10)
fs,i=10 Ns,i3f_{s,i} = \frac{10\,N_{s,i}}{3}
Clay, JAI (G.11)
fc,i=αpfLcu,if_{c,i} = \alpha_p f_L c_{u,i}
Base in sand, JAI
qb=300 Np (driven),150 Np (bored)q_b = 300\,N_p\ \text{(driven)},\quad 150\,N_p\ \text{(bored)}
Static method
f=α cu,f=β σv′f = \alpha\, c_{u,}\qquad f = \beta\, \sigma'_v
TCVN 10304 check (7.1.11)
Nc,d≤γ0γnRc,kγkN_{c,d} \le \frac{\gamma_0}{\gamma_n} \frac{R_{c,k}}{\gamma_k}
EC7 design resistance
Rc,d=Rb,kγb+Rs,kγsR_{c,d} = \frac{R_{b,k}}{\gamma_b} + \frac{R_{s,k}}{\gamma_s}

Questions

Enter the field N from the borehole log together with the hammer energy ratio, and the tool converts it to N60 = N ER/60 - the energy correction is always appropriate, because the SPT correlations were developed with hammers of about 60% efficiency. In sand it also computes (N1)60 with the overburden factor CN = (95.76/σ′v)^0.5, at most 2.0, and always uses it for the friction-angle correlation. Inside the SPT pile formulas (TCVN, Meyerhof, CP4) the overburden correction is an option, off by default, because those formulas were fitted without it.

Each SPT correlation was fitted to a different set of load tests, soils and installation practice, so a spread of 30-50% between them is normal. Pick the method your code or client expects, and treat the others as a sense check. Where the stakes are high, a static or dynamic load test on site is worth far more than any choice of formula.

Yes - choose bored installation and every method switches to its bored coefficients (150 Np instead of 300 Np at the tip in TCVN, fL = 1, the Reese & O'Neill alpha). For a barrette use the circular diameter with the same plan area, as TCVN 10304 Table G.1 notes.

It depends on the check. TCVN 10304 compares the factored design load Nc,d with the design capacity; the factor-of-safety check uses the unfactored working load; EC7 takes characteristic permanent and variable actions and applies the A1 and A2 factors itself.

Yes - export a PDF report with the figures and the full derivation, or an Excel workbook of the inputs and results. The Details tab shows every segment's friction with its numbers substituted, so the calculation can be checked line by line.

Rate this
No ratings yet
Sign in to join the discussion.
Loading…