CivilAxisCivilAxis
☕ Support🌐 Community

W 24X131 vs HE 650 A

W 24X131 is an W section from the American AISC Shapes Database; HE 650 A is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 6063.2 cm³ against 6140 cm³ of plastic modulus, a difference of 1.3%. HE 650 A is the lighter of the two at 190 kg/m against 194.9 kg/m, a saving of 2.6% on steel weight. HE 650 A is deeper, 640 mm against 622.3 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 24X131
W
HE 650 A
HE
Difference
Mass194.9 kg/m190 kg/m+2.6%
Depth622.3 mm640 mm-2.8%
Width327.7 mm300 mm+9.2%
Web thickness15.4 mm13.5 mm+14.1%
Flange thickness24.4 mm26 mm-6.2%
Area249 cm²242 cm²+2.9%
Second moment, major (Iy)167,325 cm⁴175,000 cm⁴-4.4%
Plastic modulus, major (Wpl,y)6,063.2 cm³6,140 cm³-1.3%
Elastic modulus, major (Wel,y)5,391.3 cm³5,470 cm³-1.4%
Second moment, minor (Iz)14,152 cm⁴11,700 cm⁴+21.0%
Plastic modulus, minor (Wpl,z)1,335.5 cm³1,200 cm³+11.3%
Radius of gyration, minor (iz)7.54 cm6.97 cm+8.2%
Torsion constant (It)395.4 cm⁴458 cm⁴-13.7%

W 24X131 to AISC Shapes Database v16.0; HE 650 A to EN 10365 · Continental Steel. Difference is expressed relative to HE 650 A.

How to choose between them

On stiffness, HE 650 A has the larger second moment of area: 175,000 cm⁴ against 167,325 cm⁴, a difference of 4.4%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, HE 650 A is the more efficient section: 32.3 against 31.1 cm³ per kg/m, 3.7% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: W 24X131 has 1335.5 cm³ of minor-axis plastic modulus against 1200 cm³, 11.3% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and HE to EN 10365 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 2.6% weight.

In short, HE 650 A is the stronger section and HE 650 A is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. W 24X131 has a plastic modulus of 6063.2 cm³ and HE 650 A has 6140 cm³, a difference of only 1.3% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

HE 650 A at 190 kg/m, against 194.9 kg/m for the other - a saving of 2.6%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: HE 650 A gives 6140 cm³ of plastic modulus and 175,000 cm⁴ of inertia against 6063.2 cm³ and 167,325 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and EN 10365 · Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

HE 650 A, with a second moment of area of 175,000 cm⁴ against 167,325 cm⁴ (4.4% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

W 24X131 vs H-600x300x16x27HE 650 A vs H-600x300x16x27
Rate this
No ratings yet
Sign in to join the discussion.
Loading…