CivilAxisCivilAxis
☕ Support🌐 Community

HE 650 A vs H-600x300x16x27

HE 650 A is an HE section from the European (Continental) range; H-600x300x16x27 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 6140 cm³ against 6101 cm³ of plastic modulus, a difference of 0.6%. HE 650 A is the lighter of the two at 190 kg/m against 203 kg/m, a saving of 6.4% on steel weight. HE 650 A is deeper, 640 mm against 602 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyHE 650 A
HE
H-600x300x16x27
MB & MC
Difference
Mass190 kg/m203 kg/m-6.4%
Depth640 mm602 mm+6.3%
Width300 mm304 mm-1.3%
Web thickness13.5 mm16 mm-15.6%
Flange thickness26 mm27 mm-3.7%
Area242 cm²259 cm²-6.6%
Second moment, major (Iy)175,000 cm⁴162,600 cm⁴+7.6%
Plastic modulus, major (Wpl,y)6,140 cm³6,101 cm³+0.6%
Elastic modulus, major (Wel,y)5,470 cm³5,401 cm³+1.3%
Second moment, minor (Iz)11,700 cm⁴12,680 cm⁴-7.7%
Plastic modulus, minor (Wpl,z)1,200 cm³1,292 cm³-7.1%
Radius of gyration, minor (iz)6.97 cm7 cm-0.4%
Torsion constant (It)458 cm⁴551 cm⁴-16.9%

HE 650 A to EN 10365 · Continental Steel; H-600x300x16x27 to Continental Steel. Difference is expressed relative to H-600x300x16x27.

How to choose between them

On stiffness, HE 650 A has the larger second moment of area: 175,000 cm⁴ against 162,600 cm⁴, a difference of 7.6%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, HE 650 A is the more efficient section: 32.3 against 30.1 cm³ per kg/m, 7.5% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

In short, HE 650 A is the stronger section and HE 650 A is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. HE 650 A has a plastic modulus of 6140 cm³ and H-600x300x16x27 has 6101 cm³, a difference of only 0.6% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

HE 650 A at 190 kg/m, against 203 kg/m for the other - a saving of 6.4%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-600x300x16x27 gives 6101 cm³ of plastic modulus and 162,600 cm⁴ of inertia against 6140 cm³ and 175,000 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

HE 650 A, with a second moment of area of 175,000 cm⁴ against 162,600 cm⁴ (7.6% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

UB 533×312×219 vs H-600x300x16x27W 24X131 vs HE 650 AW 24X131 vs H-600x300x16x27W 21X147 vs H-600x300x16x27
Rate this
No ratings yet
Sign in to join the discussion.