CivilAxisCivilAxis
☕ Support🌐 Community

W 24X76 vs H-600x200x12x20-118

W 24X76 is an W section from the American AISC Shapes Database; H-600x200x12x20-118 is the closest equivalent in the European (Continental) range. H-600x200x12x20-118 carries more bending: 3357 cm³ of plastic modulus against 3277.4 cm³, 2.4% more. W 24X76 is the lighter of the two at 113.1 kg/m against 118 kg/m, a saving of 4.2% on steel weight. Both are about 607 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 24X76
W
H-600x200x12x20-118
MB & MC
Difference
Mass113.1 kg/m118 kg/m-4.2%
Depth607.1 mm606 mm+0.2%
Width228.3 mm201 mm+13.6%
Web thickness11.2 mm12 mm-6.7%
Flange thickness17.3 mm20 mm-13.5%
Area144.5 cm²150 cm²-3.7%
Second moment, major (Iy)87,409 cm⁴88,320 cm⁴-1.0%
Plastic modulus, major (Wpl,y)3,277.4 cm³3,357 cm³-2.4%
Elastic modulus, major (Wel,y)2,884.1 cm³2,915 cm³-1.1%
Second moment, minor (Iz)3,434 cm⁴2,716 cm⁴+26.4%
Plastic modulus, minor (Wpl,z)468.67 cm³426 cm³+10.0%
Radius of gyration, minor (iz)4.88 cm4.26 cm+14.6%
Torsion constant (It)111.6 cm⁴147 cm⁴-24.1%

W 24X76 to AISC Shapes Database v16.0; H-600x200x12x20-118 to Continental Steel. Difference is expressed relative to H-600x200x12x20-118.

How to choose between them

On stiffness, H-600x200x12x20-118 has the larger second moment of area: 88,320 cm⁴ against 87,409 cm⁴, a difference of 1.0%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (29.0 against 28.4 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

The two diverge much more about the minor axis: W 24X76 has 468.67 cm³ of minor-axis plastic modulus against 426 cm³, 10.0% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. W sections are specified to AISC Shapes Database v16.0 and MB & MC to Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 4.2% weight.

In short, H-600x200x12x20-118 is the stronger section and W 24X76 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

H-600x200x12x20-118 is the stronger of the two in bending, with a plastic modulus of 3357 cm³ against 3277.4 cm³ - 2.4% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

W 24X76 at 113.1 kg/m, against 118 kg/m for the other - a saving of 4.2%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-600x200x12x20-118 gives 3357 cm³ of plastic modulus and 88,320 cm⁴ of inertia against 3277.4 cm³ and 87,409 cm⁴. But they are from different catalogues (AISC Shapes Database v16.0 and Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

H-600x200x12x20-118, with a second moment of area of 88,320 cm⁴ against 87,409 cm⁴ (1.0% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

UB 610×229×113 vs W 24X76UB 610×229×113 vs H-600x200x12x20-118W 24X76 vs IPE A 600W 24X76 vs S 24X80
Rate this
No ratings yet
Sign in to join the discussion.
Loading…