UB 610×229×113 vs H-600x200x12x20-118
UB 610×229×113 is an UB section from the UK Blue Book (SCI P363); H-600x200x12x20-118 is the closest equivalent in the European (Continental) range. H-600x200x12x20-118 carries more bending: 3357 cm³ of plastic modulus against 3280 cm³, 2.3% more. UB 610×229×113 is the lighter of the two at 113 kg/m against 118 kg/m, a saving of 4.2% on steel weight. Both are about 607 mm deep, so either fits the same construction zone.
| Property | UB 610×229×113 UB | H-600x200x12x20-118 MB & MC | Difference |
|---|---|---|---|
| Mass | 113 kg/m | 118 kg/m | -4.2% |
| Depth | 607.6 mm | 606 mm | +0.3% |
| Width | 228.2 mm | 201 mm | +13.5% |
| Web thickness | 11.1 mm | 12 mm | -7.5% |
| Flange thickness | 17.3 mm | 20 mm | -13.5% |
| Area | 144 cm² | 150 cm² | -4.0% |
| Second moment, major (Iy) | 87,300 cm⁴ | 88,320 cm⁴ | -1.2% |
| Plastic modulus, major (Wpl,y) | 3,280 cm³ | 3,357 cm³ | -2.3% |
| Elastic modulus, major (Wel,y) | 2,870 cm³ | 2,915 cm³ | -1.5% |
| Second moment, minor (Iz) | 3,430 cm⁴ | 2,716 cm⁴ | +26.3% |
| Plastic modulus, minor (Wpl,z) | 469 cm³ | 426 cm³ | +10.1% |
| Radius of gyration, minor (iz) | 4.88 cm | 4.26 cm | +14.6% |
| Torsion constant (It) | 111 cm⁴ | 147 cm⁴ | -24.5% |
UB 610×229×113 to BS EN 10365:2017; H-600x200x12x20-118 to Continental Steel. Difference is expressed relative to H-600x200x12x20-118.
How to choose between them
On stiffness, H-600x200x12x20-118 has the larger second moment of area: 88,320 cm⁴ against 87,300 cm⁴, a difference of 1.2%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.
Measured as bending capacity per kilogram of steel, UB 610×229×113 is the more efficient section: 29.0 against 28.4 cm³ per kg/m, 2.0% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.
The two diverge much more about the minor axis: UB 610×229×113 has 469 cm³ of minor-axis plastic modulus against 426 cm³, 10.1% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.
These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. UB sections are specified to BS EN 10365:2017 and MB & MC to Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 4.2% weight.
In short, H-600x200x12x20-118 is the stronger section and UB 610×229×113 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.