CivilAxisCivilAxis
☕ Support🌐 Community

UB 610×229×113 - Section Properties

The UB 610×229×113 is a universal beam with a mass of 113 kg/m, an overall depth of 607.6 mm and width of 228.2 mm. It has a cross-sectional area of 144 cm², a second moment of area Iᵧ of 87300 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3280 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
113 kg/m
Depth
607.6 mm
Width
228.2 mm
Area
144 cm²
Ask about capacity, buckling or detailing for UB 610×229×113.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 610×229×113

Dimension symbols for UB sections. Not to scale.

UB 610×229×113 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh607.6
Width of sectionb228.2
Web thicknesstw11.1
Flange thicknesstf17.3
Root fillet radiusr12.7
Depth between filletsd547.6

Mass and area

Mass per metremass113
Cross-sectional areaA144

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy87300
Elastic section modulus about y-axisWel,y2870
Plastic section modulus about y-axisWpl,y3280
Radius of gyration about y-axisiy24.6

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3430
Elastic section modulus about z-axisWel,z301
Plastic section modulus about z-axisWpl,z469
Radius of gyration about z-axisiz4.88

Torsion and warping

Torsion constant (St Venant)It111
Warping constantIw2.99

Classification and stability

Flange local-buckling ratiocf/tf5.54
Web local-buckling ratiocw/tw49.3
Buckling parameteru0.87
Torsional indexX38

Detailing dimensions

End clearanceC8
Notch dimension NN120
Notch dimension nn30

Surface area

Surface area per metreSA/m2.08
Surface area per tonneSA/t18.4m²/t

Is UB 610×229×113 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending32%
378.0 / 1164.4 kNm
Shear9%
126.0 / 1462.5 kN
Deflection62%
20.6 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 610×229×113

UB 610×229×113 has a mass of 113 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1356 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 610×229×113 has a depth of 607.6 mm, a width of 228.2 mm, a web thickness of 11.1 mm, a flange thickness of 17.3 mm, with a cross-sectional area of 144 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,280 cm³, and the elastic modulus Wel,y is 2,870 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1164 kNm before any stability check.

The second moment of area about the major axis, Iy, is 87,300 cm⁴, and about the minor axis Iz is 3,430 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.54 for the flange and cw/tw = 49.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 24.6 cm about the major axis and iz is 4.88 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.88 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 111 cm⁴, and the warping constant Iw is 2.99 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 610×305×179UB 610×305×149UB 610×229×140UB 610×229×125UB 610×229×101UB 610×178×100UB 610×178×92UB 610×178×82

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE A 600vs W 24X76vs S 24X80vs H-600x200x12x20-118

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…