CivilAxisCivilAxis
☕ Support🌐 Community

UB 610×229×125 - Section Properties

The UB 610×229×125 is a universal beam with a mass of 125.1 kg/m, an overall depth of 612.2 mm and width of 229 mm. It has a cross-sectional area of 159 cm², a second moment of area Iᵧ of 98600 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3680 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
125.1 kg/m
Depth
612.2 mm
Width
229 mm
Area
159 cm²
Ask about capacity, buckling or detailing for UB 610×229×125.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 610×229×125

Dimension symbols for UB sections. Not to scale.

UB 610×229×125 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh612.2
Width of sectionb229
Web thicknesstw11.9
Flange thicknesstf19.6
Root fillet radiusr12.7
Depth between filletsd547.6

Mass and area

Mass per metremass125.1
Cross-sectional areaA159

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy98600
Elastic section modulus about y-axisWel,y3220
Plastic section modulus about y-axisWpl,y3680
Radius of gyration about y-axisiy24.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz3930
Elastic section modulus about z-axisWel,z343
Plastic section modulus about z-axisWpl,z535
Radius of gyration about z-axisiz4.97

Torsion and warping

Torsion constant (St Venant)It154
Warping constantIw3.45

Classification and stability

Flange local-buckling ratiocf/tf4.89
Web local-buckling ratiocw/tw46
Buckling parameteru0.875
Torsional indexX34

Detailing dimensions

End clearanceC8
Notch dimension NN120
Notch dimension nn34

Surface area

Surface area per metreSA/m2.09
Surface area per tonneSA/t16.7m²/t

Is UB 610×229×125 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending31%
405.0 / 1306.4 kNm
Shear9%
135.0 / 1568.8 kN
Deflection59%
19.6 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 610×229×125

UB 610×229×125 has a mass of 125.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1501 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 610×229×125 has a depth of 612.2 mm, a width of 229 mm, a web thickness of 11.9 mm, a flange thickness of 19.6 mm, with a cross-sectional area of 159 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,680 cm³, and the elastic modulus Wel,y is 3,220 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1306 kNm before any stability check.

The second moment of area about the major axis, Iy, is 98,600 cm⁴, and about the minor axis Iz is 3,930 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.89 for the flange and cw/tw = 46 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 24.9 cm about the major axis and iz is 4.97 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.97 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 154 cm⁴, and the warping constant Iw is 3.45 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 610×305×238UB 610×305×179UB 610×305×149UB 610×229×140UB 610×229×113UB 610×229×101UB 610×178×100UB 610×178×92

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 600vs HE 600 AAvs W 24X84vs S 24X90vs H-600x200x13x23

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…