CivilAxisCivilAxis
☕ Support🌐 Community

UB 610×305×238 - Section Properties

The UB 610×305×238 is a universal beam with a mass of 238.1 kg/m, an overall depth of 635.8 mm and width of 311.4 mm. It has a cross-sectional area of 303 cm², a second moment of area Iᵧ of 209000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 7490 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
238.1 kg/m
Depth
635.8 mm
Width
311.4 mm
Area
303 cm²
Ask about capacity, buckling or detailing for UB 610×305×238.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 610×305×238

Dimension symbols for UB sections. Not to scale.

UB 610×305×238 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh635.8
Width of sectionb311.4
Web thicknesstw18.4
Flange thicknesstf31.4
Root fillet radiusr16.5
Depth between filletsd540

Mass and area

Mass per metremass238.1
Cross-sectional areaA303

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy209000
Elastic section modulus about y-axisWel,y6590
Plastic section modulus about y-axisWpl,y7490
Radius of gyration about y-axisiy26.3

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz15800
Elastic section modulus about z-axisWel,z1020
Plastic section modulus about z-axisWpl,z1570
Radius of gyration about z-axisiz7.23

Torsion and warping

Torsion constant (St Venant)It785
Warping constantIw14.5

Classification and stability

Flange local-buckling ratiocf/tf4.14
Web local-buckling ratiocw/tw29.3
Buckling parameteru0.886
Torsional indexX21.3

Detailing dimensions

End clearanceC11
Notch dimension NN158
Notch dimension nn48

Surface area

Surface area per metreSA/m2.45
Surface area per tonneSA/t10.3m²/t

Is UB 610×305×238 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending34%
891.0 / 2658.9 kNm
Shear12%
297.0 / 2532.9 kN
Deflection61%
20.3 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 610×305×238

UB 610×305×238 has a mass of 238.1 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2857 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 610×305×238 has a depth of 635.8 mm, a width of 311.4 mm, a web thickness of 18.4 mm, a flange thickness of 31.4 mm, with a cross-sectional area of 303 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 7,490 cm³, and the elastic modulus Wel,y is 6,590 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2659 kNm before any stability check.

The second moment of area about the major axis, Iy, is 209,000 cm⁴, and about the minor axis Iz is 15,800 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 4.14 for the flange and cw/tw = 29.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 26.3 cm about the major axis and iz is 7.23 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.23 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 785 cm⁴, and the warping constant Iw is 14.5 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 686×254×170UB 686×254×152UB 686×254×140UB 686×254×125UB 610×305×179UB 610×305×149UB 610×229×140UB 610×229×125

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs HE 650 Bvs W 24X162

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…