UB 686×254×125 - Section Properties

The UB 686×254×125 is a universal beam with a mass of 125.2 kg/m, an overall depth of 677.9 mm and width of 253 mm. It has a cross-sectional area of 159 cm², a second moment of area Iᵧ of 118000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3990 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
125.2 kg/m
Depth
677.9 mm
Width
253 mm
Area
159 cm²
Ask about capacity, buckling or detailing for UB 686×254×125.
🔍 Open the full Steel Catalogue →📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 686×254×125

Dimension symbols for UB sections. Not to scale.

UB 686×254×125 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh677.9
Width of sectionb253
Web thicknesstw11.7
Flange thicknesstf16.2
Root fillet radiusr15.2
Depth between filletsd615.1

Mass and area

Mass per metremass125.2
Cross-sectional areaA159

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy118000
Elastic section modulus about y-axisWel,y3480
Plastic section modulus about y-axisWpl,y3990
Radius of gyration about y-axisiy27.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz4380
Elastic section modulus about z-axisWel,z346
Plastic section modulus about z-axisWpl,z542
Radius of gyration about z-axisiz5.24

Torsion and warping

Torsion constant (St Venant)It116
Warping constantIw4.8

Classification and stability

Flange local-buckling ratiocf/tf6.51
Web local-buckling ratiocw/tw52.6
Buckling parameteru0.863
Torsional indexX43.8

Detailing dimensions

End clearanceC8
Notch dimension NN132
Notch dimension nn32

Surface area

Surface area per metreSA/m2.32
Surface area per tonneSA/t18.5m²/t

Is UB 686×254×125 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

✅Passes - 59% utilised, deflection governs
Bending34%
486.0 / 1416.5 kNm
Shear9%
162.0 / 1718.5 kN
Deflection59%
19.6 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 686×254×125

UB 686×254×125 has a mass of 125.2 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1502 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 686×254×125 has a depth of 677.9 mm, a width of 253 mm, a web thickness of 11.7 mm, a flange thickness of 16.2 mm, with a cross-sectional area of 159 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,990 cm³, and the elastic modulus Wel,y is 3,480 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1416 kNm before any stability check.

The second moment of area about the major axis, Iy, is 118,000 cm⁴, and about the minor axis Iz is 4,380 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 6.51 for the flange and cw/tw = 52.6 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 27.2 cm about the major axis and iz is 5.24 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.24 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 116 cm⁴, and the warping constant Iw is 4.8 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 762×267×134UB 686×254×170UB 686×254×152UB 686×254×140UB 610×305×238UB 610×305×179UB 610×305×149UB 610×229×140

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 27X84 →

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE) →📘 Section modulus explained: elastic (Wel) vs plastic (Wpl) →📘 IPE vs HE (HEA/HEB): choosing a European steel beam →
All UB sizes →
Universal Beams (UB)
Full steel section tables →
Every UB, UC, hollow, channel & angle section
Open the interactive tool →
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…