CivilAxisCivilAxis
☕ Support🌐 Community

UB 762×267×134 - Section Properties

The UB 762×267×134 is a universal beam with a mass of 133.9 kg/m, an overall depth of 750 mm and width of 264.4 mm. It has a cross-sectional area of 171 cm², a second moment of area Iᵧ of 151000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 4640 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
133.9 kg/m
Depth
750 mm
Width
264.4 mm
Area
171 cm²
Ask about capacity, buckling or detailing for UB 762×267×134.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 762×267×134

Dimension symbols for UB sections. Not to scale.

UB 762×267×134 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh750
Width of sectionb264.4
Web thicknesstw12
Flange thicknesstf15.5
Root fillet radiusr16.5
Depth between filletsd686

Mass and area

Mass per metremass133.9
Cross-sectional areaA171

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy151000
Elastic section modulus about y-axisWel,y4020
Plastic section modulus about y-axisWpl,y4640
Radius of gyration about y-axisiy29.7

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz4790
Elastic section modulus about z-axisWel,z362
Plastic section modulus about z-axisWpl,z570
Radius of gyration about z-axisiz5.3

Torsion and warping

Torsion constant (St Venant)It119
Warping constantIw6.46

Classification and stability

Flange local-buckling ratiocf/tf7.08
Web local-buckling ratiocw/tw57.2
Buckling parameteru0.853
Torsional indexX49.8

Detailing dimensions

End clearanceC8
Notch dimension NN138
Notch dimension nn32

Surface area

Surface area per metreSA/m2.51
Surface area per tonneSA/t18.7m²/t

Is UB 762×267×134 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 59% utilised, deflection governs
Bending38%
621.0 / 1647.2 kNm
Shear11%
207.0 / 1967.8 kN
Deflection59%
19.6 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 762×267×134

UB 762×267×134 has a mass of 133.9 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 1607 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 762×267×134 has a depth of 750 mm, a width of 264.4 mm, a web thickness of 12 mm, a flange thickness of 15.5 mm, with a cross-sectional area of 171 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 4,640 cm³, and the elastic modulus Wel,y is 4,020 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1647 kNm before any stability check.

The second moment of area about the major axis, Iy, is 151,000 cm⁴, and about the minor axis Iz is 4,790 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.08 for the flange and cw/tw = 57.2 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 29.7 cm about the major axis and iz is 5.3 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.3 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 119 cm⁴, and the warping constant Iw is 6.46 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 838×292×176UB 762×267×197UB 762×267×173UB 762×267×147UB 686×254×170UB 686×254×152UB 686×254×140UB 686×254×125

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 750 x 134vs W 30X90

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…