UB 762×267×173 - Section Properties

The UB 762×267×173 is a universal beam with a mass of 173 kg/m, an overall depth of 762.2 mm and width of 266.7 mm. It has a cross-sectional area of 220 cm², a second moment of area Iᵧ of 205000 cm⁴, a plastic modulus Wₚₗ,ᵧ of 6200 cm³, tabulated by CivilAxis from BS EN 10365:2017 (SCI P363 Blue Book).

Mass
173 kg/m
Depth
762.2 mm
Width
266.7 mm
Area
220 cm²
Ask about capacity, buckling or detailing for UB 762×267×173.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
UB section profile showing the dimension symbols used for UB 762×267×173

Dimension symbols for UB sections. Not to scale.

UB 762×267×173 section properties to BS EN 10365:2017.

Geometry

Depth of sectionh762.2
Width of sectionb266.7
Web thicknesstw14.3
Flange thicknesstf21.6
Root fillet radiusr16.5
Depth between filletsd686

Mass and area

Mass per metremass173
Cross-sectional areaA220

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy205000
Elastic section modulus about y-axisWel,y5390
Plastic section modulus about y-axisWpl,y6200
Radius of gyration about y-axisiy30.5

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz6850
Elastic section modulus about z-axisWel,z514
Plastic section modulus about z-axisWpl,z807
Radius of gyration about z-axisiz5.58

Torsion and warping

Torsion constant (St Venant)It267
Warping constantIw9.39

Classification and stability

Flange local-buckling ratiocf/tf5.08
Web local-buckling ratiocw/tw48
Buckling parameteru0.865
Torsional indexX38

Detailing dimensions

End clearanceC9
Notch dimension NN138
Notch dimension nn40

Surface area

Surface area per metreSA/m2.53
Surface area per tonneSA/t14.6m²/t

Is UB 762×267×173 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending39%
864.0 / 2201.0 kNm
Shear12%
288.0 / 2357.1 kN
Deflection60%
20.1 / 33.3 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about UB 762×267×173

UB 762×267×173 has a mass of 173 kg/m, tabulated to BS EN 10365:2017. A 12 m length therefore weighs about 2076 kg, which is the figure to use for a steel take-off or when checking a lift.

UB 762×267×173 has a depth of 762.2 mm, a width of 266.7 mm, a web thickness of 14.3 mm, a flange thickness of 21.6 mm, with a cross-sectional area of 220 cm². These are the nominal dimensions from BS EN 10365:2017; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 6,200 cm³, and the elastic modulus Wel,y is 5,390 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 2201 kNm before any stability check.

The second moment of area about the major axis, Iy, is 205,000 cm⁴, and about the minor axis Iz is 6,850 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 5.08 for the flange and cw/tw = 48 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 30.5 cm about the major axis and iz is 5.58 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 5.58 cm a 0.6 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 267 cm⁴, and the warping constant Iw is 9.39 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related UB sizes

UB 838×292×226UB 838×292×194UB 838×292×176UB 762×267×197UB 762×267×147UB 762×267×134UB 686×254×170UB 686×254×152

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs IPE 750 x 173vs HE 800 AAvs W 30X116

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All UB sizes
Universal Beams (UB)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…