CivilAxisCivilAxis
☕ Support🌐 Community

W 24X84 vs S 24X90

W 24X84 is an W section from the American AISC Shapes Database; S 24X90 is the closest equivalent in the American AISC Shapes Database. They are close to interchangeable in bending: 3670.7 cm³ against 3637.9 cm³ of plastic modulus, a difference of 0.9%. W 24X84 is the lighter of the two at 125 kg/m against 133.9 kg/m, a saving of 6.6% on steel weight. Both are about 611 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyW 24X84
W
S 24X90
S
Difference
Mass125 kg/m133.9 kg/m-6.6%
Depth612.1 mm609.6 mm+0.4%
Width229.1 mm181.1 mm+26.5%
Web thickness11.9 mm15.9 mm-25.2%
Flange thickness19.6 mm22.1 mm-11.3%
Area159.4 cm²171 cm²-6.8%
Second moment, major (Iy)98,647 cm⁴93,652 cm⁴+5.3%
Plastic modulus, major (Wpl,y)3,670.7 cm³3,637.9 cm³+0.9%
Elastic modulus, major (Wel,y)3,211.9 cm³3,064.4 cm³+4.8%
Second moment, minor (Iz)3,929 cm⁴1,861 cm⁴+111.1%
Plastic modulus, minor (Wpl,z)534.22 cm³367.07 cm³+45.5%
Radius of gyration, minor (iz)4.95 cm3.3 cm+50.0%
Torsion constant (It)154 cm⁴251.8 cm⁴-38.8%

W 24X84 to AISC Shapes Database v16.0; S 24X90 to AISC Shapes Database v16.0. Difference is expressed relative to S 24X90.

How to choose between them

On stiffness, W 24X84 has the larger second moment of area: 98,647 cm⁴ against 93,652 cm⁴, a difference of 5.3%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, W 24X84 is the more efficient section: 29.4 against 27.2 cm³ per kg/m, 8.1% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

The two diverge much more about the minor axis: W 24X84 has 534.22 cm³ of minor-axis plastic modulus against 367.07 cm³, 45.5% more. If the member sees any minor-axis bending, or if it is unrestrained over a long length and lateral-torsional buckling governs, that gap decides the comparison even though the major-axis numbers looked equivalent.

In short, W 24X84 is the stronger section and W 24X84 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. W 24X84 has a plastic modulus of 3670.7 cm³ and S 24X90 has 3637.9 cm³, a difference of only 0.9% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

W 24X84 at 125 kg/m, against 133.9 kg/m for the other - a saving of 6.6%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: S 24X90 gives 3637.9 cm³ of plastic modulus and 93,652 cm⁴ of inertia against 3670.7 cm³ and 98,647 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

W 24X84, with a second moment of area of 98,647 cm⁴ against 93,652 cm⁴ (5.3% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

IPE 600 vs W 24X84IPE 600 vs S 24X90UB 610×229×125 vs W 24X84UB 610×229×125 vs S 24X90W 24X84 vs HE 600 AAW 24X84 vs H-600x200x13x23
Rate this
No ratings yet
Sign in to join the discussion.
Loading…