CivilAxisCivilAxis
☕ Support🌐 Community

HE 500 A vs H-500x300x13x21

HE 500 A is an HE section from the European (Continental) range; H-500x300x13x21 is the closest equivalent in the European (Continental) range. HE 500 A carries more bending: 3950 cm³ of plastic modulus against 3792 cm³, 4.2% more. H-500x300x13x21 is the lighter of the two at 150 kg/m against 155 kg/m, a saving of 3.3% on steel weight. Both are about 492 mm deep, so either fits the same construction zone.

Section properties side by side. Bold marks the more favourable value where one is.
PropertyHE 500 A
HE
H-500x300x13x21
MB & MC
Difference
Mass155 kg/m150 kg/m+3.3%
Depth490 mm494 mm-0.8%
Width300 mm302 mm-0.7%
Web thickness12 mm13 mm-7.7%
Flange thickness23 mm21 mm+9.5%
Area198 cm²191 cm²+3.7%
Second moment, major (Iy)87,000 cm⁴83,810 cm⁴+3.8%
Plastic modulus, major (Wpl,y)3,950 cm³3,792 cm³+4.2%
Elastic modulus, major (Wel,y)3,550 cm³3,393 cm³+4.6%
Second moment, minor (Iz)10,400 cm⁴9,663 cm⁴+7.6%
Plastic modulus, minor (Wpl,z)1,060 cm³984 cm³+7.7%
Radius of gyration, minor (iz)7.24 cm7.11 cm+1.8%
Torsion constant (It)318 cm⁴265 cm⁴+20.0%

HE 500 A to EN 10365 · Continental Steel; H-500x300x13x21 to Continental Steel. Difference is expressed relative to H-500x300x13x21.

How to choose between them

On stiffness, HE 500 A has the larger second moment of area: 87,000 cm⁴ against 83,810 cm⁴, a difference of 3.8%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram, the two are equally efficient (25.5 against 25.3 cm³ per kg/m), so on a pure steel-tonnage basis there is nothing to choose between them. The decision comes down to availability, connection detailing and what the rest of the frame uses.

In short, HE 500 A is the stronger section and H-500x300x13x21 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

HE 500 A is the stronger of the two in bending, with a plastic modulus of 3950 cm³ against 3792 cm³ - 4.2% more. At the same steel grade that translates directly into moment capacity, since M_pl,Rd = W_pl x f_y / gamma_M0.

H-500x300x13x21 at 150 kg/m, against 155 kg/m for the other - a saving of 3.3%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: H-500x300x13x21 gives 3792 cm³ of plastic modulus and 83,810 cm⁴ of inertia against 3950 cm³ and 87,000 cm⁴. Re-check deflection and the connection details before swapping, since the flange and web thicknesses differ.

HE 500 A, with a second moment of area of 87,000 cm⁴ against 83,810 cm⁴ (3.8% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

UB 457×191×161 vs HE 500 AUB 457×191×161 vs H-500x300x13x21W 18X106 vs H-500x300x13x21
Rate this
No ratings yet
Sign in to join the discussion.