H-500x300x13x21 - Section Properties

The H-500x300x13x21 is a European narrow I-beam with a mass of 150 kg/m, an overall depth of 494 mm and width of 302 mm. It has a cross-sectional area of 191 cm², a second moment of area Iᵧ of 83810 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3792 cm³, tabulated by CivilAxis from Continental Steel.

Mass
150 kg/m
Depth
494 mm
Width
302 mm
Area
191 cm²
Ask about capacity, buckling or detailing for H-500x300x13x21.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-500x300x13x21

Dimension symbols for MB & MC sections. Not to scale.

H-500x300x13x21 section properties to Continental Steel.

Geometry

Depth of sectionh494
Width of sectionb302
Web thicknesstw13
Flange thicknesstf21
Root fillet radiusr26
Depth between filletsd400

Mass and area

Mass per metremass150
Cross-sectional areaA191

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy83810
Elastic section modulus about y-axisWel,y3393
Plastic section modulus about y-axisWpl,y3792
Radius of gyration about y-axisiy20.9

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz9663
Elastic section modulus about z-axisWel,z640
Plastic section modulus about z-axisWpl,z984
Radius of gyration about z-axisiz7.11

Torsion and warping

Torsion constant (St Venant)It265
Warping constantIw5.4

Classification and stability

Flange local-buckling ratiocf/tf7.19
Web local-buckling ratiocw/tw30.8
Buckling parameteru0.888
Torsional indexX22.8

Detailing dimensions

End clearanceC9
Notch dimension NN155
Notch dimension nn47

Surface area

Surface area per metreSA/m2.13

Is H-500x300x13x21 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
431.3 / 1346.2 kNm
Shear11%
172.5 / 1594.8 kN
Deflection61%
17.0 / 27.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-500x300x13x21

H-500x300x13x21 has a mass of 150 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1800 kg, which is the figure to use for a steel take-off or when checking a lift.

H-500x300x13x21 has a depth of 494 mm, a width of 302 mm, a web thickness of 13 mm, a flange thickness of 21 mm, with a cross-sectional area of 191 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,792 cm³, and the elastic modulus Wel,y is 3,393 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1346 kNm before any stability check.

The second moment of area about the major axis, Iy, is 83,810 cm⁴, and about the minor axis Iz is 9,663 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.19 for the flange and cw/tw = 30.8 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 20.9 cm about the major axis and iz is 7.11 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.11 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 265 cm⁴, and the warping constant Iw is 5.4 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-500x300x11x15-111H-500x300x11x15-114H-500x300x11x18-125H-500x300x11x18-128H-600x200x8x13H-600x200x10x15-92.5H-600x200x10x15-94.6H-600x200x11x17-103

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 457×191×161vs W 18X106vs HE 500 A

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…