CivilAxisCivilAxis
☕ Support🌐 Community

H-600x200x8x13 - Section Properties

The H-600x200x8x13 is a European narrow I-beam with a mass of 79 kg/m, an overall depth of 592 mm and width of 197 mm. It has a cross-sectional area of 101 cm², a second moment of area Iᵧ of 58240 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2239 cm³, tabulated by CivilAxis from Continental Steel.

Mass
79 kg/m
Depth
592 mm
Width
197 mm
Area
101 cm²
Ask about capacity, buckling or detailing for H-600x200x8x13.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-600x200x8x13

Dimension symbols for MB & MC sections. Not to scale.

H-600x200x8x13 section properties to Continental Steel.

Geometry

Depth of sectionh592
Width of sectionb197
Web thicknesstw8
Flange thicknesstf13
Root fillet radiusr22
Depth between filletsd522

Mass and area

Mass per metremass79
Cross-sectional areaA101

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy58240
Elastic section modulus about y-axisWel,y1968
Plastic section modulus about y-axisWpl,y2239
Radius of gyration about y-axisiy24.1

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1665
Elastic section modulus about z-axisWel,z169
Plastic section modulus about z-axisWpl,z265
Radius of gyration about z-axisiz4.07

Torsion and warping

Torsion constant (St Venant)It53
Warping constantIw1.4

Classification and stability

Flange local-buckling ratiocf/tf7.58
Web local-buckling ratiocw/tw65.3
Buckling parameteru0.87
Torsional indexX45.2

Detailing dimensions

End clearanceC6
Notch dimension NN105
Notch dimension nn35

Surface area

Surface area per metreSA/m1.92

Is H-600x200x8x13 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
243.0 / 794.8 kNm
Shear7%
81.0 / 1158.8 kN
Deflection60%
19.9 / 33.3 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-600x200x8x13

H-600x200x8x13 has a mass of 79 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 948 kg, which is the figure to use for a steel take-off or when checking a lift.

H-600x200x8x13 has a depth of 592 mm, a width of 197 mm, a web thickness of 8 mm, a flange thickness of 13 mm, with a cross-sectional area of 101 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,239 cm³, and the elastic modulus Wel,y is 1,968 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 795 kNm before any stability check.

The second moment of area about the major axis, Iy, is 58,240 cm⁴, and about the minor axis Iz is 1,665 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 7.58 for the flange and cw/tw = 65.3 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 24.1 cm about the major axis and iz is 4.07 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.07 cm a 0.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 53 cm⁴, and the warping constant Iw is 1.4 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-500x300x11x15-114H-500x300x11x18-125H-500x300x11x18-128H-500x300x13x21H-600x200x10x15-92.5H-600x200x10x15-94.6H-600x200x11x17-103H-600x200x11x17-106

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs UB 610×178×82vs W 24X55

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…