CivilAxisCivilAxis
☕ Support🌐 Community

H-500x300x11x18-128 - Section Properties

The H-500x300x11x18-128 is a European narrow I-beam with a mass of 128 kg/m, an overall depth of 488 mm and width of 300 mm. It has a cross-sectional area of 164 cm², a second moment of area Iᵧ of 70960 cm⁴, a plastic modulus Wₚₗ,ᵧ of 3228 cm³, tabulated by CivilAxis from Continental Steel.

Mass
128 kg/m
Depth
488 mm
Width
300 mm
Area
164 cm²
Ask about capacity, buckling or detailing for H-500x300x11x18-128.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
MB & MC section profile showing the dimension symbols used for H-500x300x11x18-128

Dimension symbols for MB & MC sections. Not to scale.

H-500x300x11x18-128 section properties to Continental Steel.

Geometry

Depth of sectionh488
Width of sectionb300
Web thicknesstw11
Flange thicknesstf18
Root fillet radiusr26
Depth between filletsd400

Mass and area

Mass per metremass128
Cross-sectional areaA164

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy70960
Elastic section modulus about y-axisWel,y2908
Plastic section modulus about y-axisWpl,y3228
Radius of gyration about y-axisiy20.8

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz8118
Elastic section modulus about z-axisWel,z541
Plastic section modulus about z-axisWpl,z830
Radius of gyration about z-axisiz7.05

Torsion and warping

Torsion constant (St Venant)It172
Warping constantIw4.48

Classification and stability

Flange local-buckling ratiocf/tf8.33
Web local-buckling ratiocw/tw36.4
Buckling parameteru0.889
Torsional indexX25.9

Detailing dimensions

End clearanceC8
Notch dimension NN155
Notch dimension nn44

Surface area

Surface area per metreSA/m2.11

Is H-500x300x11x18-128 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending31%
356.3 / 1145.9 kNm
Shear10%
142.5 / 1380.2 kN
Deflection60%
16.6 / 27.8 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about H-500x300x11x18-128

H-500x300x11x18-128 has a mass of 128 kg/m, tabulated to Continental Steel. A 12 m length therefore weighs about 1536 kg, which is the figure to use for a steel take-off or when checking a lift.

H-500x300x11x18-128 has a depth of 488 mm, a width of 300 mm, a web thickness of 11 mm, a flange thickness of 18 mm, with a cross-sectional area of 164 cm². These are the nominal dimensions from Continental Steel; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 3,228 cm³, and the elastic modulus Wel,y is 2,908 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 1146 kNm before any stability check.

The second moment of area about the major axis, Iy, is 70,960 cm⁴, and about the minor axis Iz is 8,118 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

Its local-buckling ratios are cf/tf = 8.33 for the flange and cw/tw = 36.4 for the web. EN 1993-1-1 Table 5.2 compares these against limits scaled by epsilon = sqrt(235/f_y), so the class depends on the steel grade as well as the geometry - the same section can be Class 1 in S275 and Class 3 in S355. Use the Capacity tab on this page for the classification at a specific grade.

iy is 20.8 cm about the major axis and iz is 7.05 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.05 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 172 cm⁴, and the warping constant Iw is 4.48 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related MB & MC sizes

H-500x200x12x22H-500x300x11x15-111H-500x300x11x15-114H-500x300x11x18-125H-500x300x13x21H-600x200x8x13H-600x200x10x15-92.5H-600x200x10x15-94.6

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All MB & MC sizes
Narrow I-Beams (MB & MC)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…