CivilAxisCivilAxis
☕ Support🌐 Community

SHS 260×260×8.8 vs SHS 250×250×10

SHS 260×260×8.8 is an SHS Hot-finished section from the UK Blue Book (SCI P363); SHS 250×250×10 is the closest equivalent in the European (Continental) range. They are close to interchangeable in bending: 822 cm³ against 822 cm³ of plastic modulus, a difference of 0.0%. SHS 260×260×8.8 is the lighter of the two at 68.8 kg/m against 72.7 kg/m, a saving of 5.4% on steel weight. SHS 260×260×8.8 is deeper, 260 mm against 250 mm, which matters where the floor zone is tight.

Section properties side by side. Bold marks the more favourable value where one is.
PropertySHS 260×260×8.8
SHS Hot-finished
SHS 250×250×10
SHS Cold-formed
Difference
Mass68.8 kg/m72.7 kg/m-5.4%
Depth260 mm250 mm+4.0%
Width260 mm250 mm+4.0%
Web thickness0 mm0 mmsame
Flange thickness0 mm0 mmsame
Area87.6 cm²92.6 cm²-5.4%
Second moment, major (Iy)9,160 cm⁴8,707 cm⁴+5.2%
Plastic modulus, major (Wpl,y)822 cm³822 cm³same
Elastic modulus, major (Wel,y)705 cm³697 cm³+1.1%
Second moment, minor (Iz)9,160 cm⁴8,707 cm⁴+5.2%
Plastic modulus, minor (Wpl,z)822 cm³822 cm³same
Radius of gyration, minor (iz)10.2 cm9.7 cm+5.2%
Torsion constant (It)14,200 cm⁴14,200 cm⁴same

SHS 260×260×8.8 to BS EN 10210-2:2006; SHS 250×250×10 to EN 10219 · Continental Steel. Difference is expressed relative to SHS 250×250×10.

How to choose between them

On stiffness, SHS 260×260×8.8 has the larger second moment of area: 9,160 cm⁴ against 8,707 cm⁴, a difference of 5.2%. This matters more often than the strength comparison, because on normal floor spans deflection rather than bending capacity sets the beam size - so if the two are close on modulus but apart on inertia, the stiffer one is usually the better answer even when it is not the stronger one.

Measured as bending capacity per kilogram of steel, SHS 260×260×8.8 is the more efficient section: 11.9 against 11.3 cm³ per kg/m, 5.7% better. Over a floor of repeated beams that difference is real tonnage, though it is often outweighed by whichever section the fabricator can actually source.

These come from different catalogues, so treat the swap as a design change rather than a like-for-like substitution. SHS Hot-finished sections are specified to BS EN 10210-2:2006 and SHS Cold-formed to EN 10219 · Continental Steel; the steel grades, tolerances and available lengths differ, connection details and bolt gauges are set out differently, and the two are rarely both stocked in the same market. Check availability before changing a section on a drawing to save 5.4% weight.

In short, SHS 250×250×10 is the stronger section and SHS 260×260×8.8 is the lighter one; where those are the same section, it is the clear choice, and where they are not, decide on whether your design is governed by capacity or by tonnage.

Common questions

They are effectively equal in bending. SHS 260×260×8.8 has a plastic modulus of 822 cm³ and SHS 250×250×10 has 822 cm³, a difference of only 0.0% - within the margin that section choice normally turns on. Compare stiffness and availability instead.

SHS 260×260×8.8 at 68.8 kg/m, against 72.7 kg/m for the other - a saving of 5.4%. Over a repeated floor beam that is a real cost difference, but check it against the deflection case before taking it.

Structurally it is the closest equivalent we hold: SHS 250×250×10 gives 822 cm³ of plastic modulus and 8,707 cm⁴ of inertia against 822 cm³ and 9,160 cm⁴. But they are from different catalogues (BS EN 10210-2:2006 and EN 10219 · Continental Steel), so this is a design change, not a drop-in swap: re-check deflection, connection detailing and local availability.

SHS 260×260×8.8, with a second moment of area of 9,160 cm⁴ against 8,707 cm⁴ (5.2% more). Deflection under a uniform load goes as 5wL⁴/384EI, so it is inversely proportional to I - on a span where the deflection limit governs rather than strength, this is the number that decides the section.

Related comparisons

SHS 250×250×10 vs CF SHS 250×250×10SHS 260×260×8.8 vs CF SHS 250×250×10SHS 260×260×8.8 vs SHS 250×250×10
Rate this
No ratings yet
Sign in to join the discussion.
Loading…