SHS 260×260×8.8 - Section Properties

The SHS 260×260×8.8 is a square hollow section with a mass of 68.8 kg/m, an overall depth of 260 mm and width of 260 mm and a wall thickness of 8.8 mm. It has a cross-sectional area of 87.6 cm², a second moment of area Iᵧ of 9160 cm⁴, a plastic modulus Wₚₗ,ᵧ of 822 cm³, tabulated by CivilAxis from BS EN 10210-2:2006 (SCI P363 Blue Book).

Mass
68.8 kg/m
Depth
260 mm
Width
260 mm
Wall thickness
8.8 mm
Area
87.6 cm²
Ask about capacity, buckling or detailing for SHS 260×260×8.8.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
SHS Hot-finished section profile showing the dimension symbols used for SHS 260×260×8.8

Dimension symbols for SHS Hot-finished sections. Not to scale.

SHS 260×260×8.8 section properties to BS EN 10210-2:2006.

Geometry

Depth of sectionh260
Width of sectionb260
Wall thicknesst8.8

Mass and area

Mass per metremass68.8
Cross-sectional areaA87.6

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy9160
Elastic section modulus about y-axisWel,y705
Plastic section modulus about y-axisWpl,y822
Radius of gyration about y-axisiy10.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz9160
Elastic section modulus about z-axisWel,z705
Plastic section modulus about z-axisWpl,z822
Radius of gyration about z-axisiz10.2

Torsion and warping

Torsion constant (St Venant)It14200
Section modulus for torsionWt1040

Surface area

Surface area per metreSA/m1.02
Surface area per tonneSA/t14.8m²/t

Is SHS 260×260×8.8 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 61% utilised, deflection governs
Bending32%
93.8 / 291.8 kNm
Shear8%
75.0 / 897.7 kN
Deflection61%
8.5 / 13.9 mm

Class 1 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about SHS 260×260×8.8

SHS 260×260×8.8 has a mass of 68.8 kg/m, tabulated to BS EN 10210-2:2006. A 12 m length therefore weighs about 826 kg, which is the figure to use for a steel take-off or when checking a lift.

SHS 260×260×8.8 has a depth of 260 mm, a width of 260 mm, a wall thickness of 8.8 mm, with a cross-sectional area of 87.6 cm². These are the nominal dimensions from BS EN 10210-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 822 cm³, and the elastic modulus Wel,y is 705 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 292 kNm before any stability check.

The second moment of area about the major axis, Iy, is 9,160 cm⁴, and about the minor axis Iz is 9,160 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 10.2 cm about the major axis and iz is 10.2 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 10.2 cm a 1.0 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 14,200 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related SHS Hot-finished sizes

SHS 250×250×16SHS 260×260×6.3SHS 260×260×7.1SHS 260×260×8SHS 260×260×10SHS 260×260×12.5SHS 260×260×14.2SHS 260×260×16

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CF SHS 250×250×10vs SHS 250×250×10vs SHS 250×250×10

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All SHS Hot-finished sizes
Square Hollow Sections - Hot-finished (BS EN 10210)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…