HP 12X89 - Section Properties

The HP 12X89 is a steel section with a mass of 132.4 kg/m, an overall depth of 315 mm and width of 312.4 mm. It has a cross-sectional area of 167.1 cm², a second moment of area Iᵧ of 28845 cm⁴, a plastic modulus Wₚₗ,ᵧ of 2081.2 cm³, tabulated by CivilAxis from AISC Shapes Database v16.0.

Mass
89 lb/ft (132.4 kg/m)
Depth
12.4 in (315 mm)
Width
12.3 in (312.4 mm)
Area
25.9 in² (167.1 cm²)
Ask about capacity, buckling or detailing for HP 12X89.
🔍 Open the full Steel Catalogue
or pick a unit on any row
HP section profile showing the dimension symbols used for HP 12X89

Dimension symbols for HP sections. Not to scale.

HP 12X89 section properties to AISC Shapes Database v16.0.

Geometry

Depth of sectionh12.4
315 mm
Width of sectionb12.3
312.4 mm
Web thicknesstw0.72
18.3 mm
Flange thicknesstf0.72
18.3 mm

Mass and area

Mass per metremass89
132.4 kg/m
Cross-sectional areaA25.9
167.1 cm²

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy693
28845 cm⁴
Elastic section modulus about y-axisWel,y112
1835.4 cm³
Plastic section modulus about y-axisWpl,y127
2081.2 cm³
Radius of gyration about y-axisiy5.17
13.13 cm

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz224
9324 cm⁴
Elastic section modulus about z-axisWel,z36.4
596.49 cm³
Plastic section modulus about z-axisWpl,z56
917.68 cm³
Radius of gyration about z-axisiz2.94
7.47 cm

Torsion and warping

Torsion constant (St Venant)It4.92
204.8 cm⁴
Warping constantIw7640
2.05 dm⁶

Is HP 12X89 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending30%
221.8 / 738.8 kNm
Shear12%
136.5 / 1150.0 kN
Deflection60%
10.7 / 18.1 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about HP 12X89

HP 12X89 has a mass of 89 lb/ft (132.4 kg/m), tabulated to AISC Shapes Database v16.0. A 12 m length therefore weighs about 1589 kg, which is the figure to use for a steel take-off or when checking a lift.

HP 12X89 has a depth of 12.4 in (315 mm), a width of 12.3 in (312.4 mm), a web thickness of 0.72 in (18.3 mm), a flange thickness of 0.72 in (18.3 mm), with a cross-sectional area of 25.9 in² (167.1 cm²). These are the nominal dimensions from AISC Shapes Database v16.0; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 2,081.2 cm³, and the elastic modulus Wel,y is 1,835.4 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 739 kNm before any stability check.

The second moment of area about the major axis, Iy, is 28,845 cm⁴, and about the minor axis Iz is 9,324 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 13.13 cm about the major axis and iz is 7.47 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.47 cm a 0.7 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 204.8 cm⁴, and the warping constant Iw is 2.05 dm⁶. Open sections carry torsion mainly by warping rather than uniform torsion, which is why Iw appears in the lateral-torsional buckling resistance - both values feed M_b,Rd.

Related HP sizes

HP 14X117HP 14X102HP 14X89HP 14X73HP 12X84HP 12X74HP 12X63HP 12X53

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs W 12X87vs HE 320 B

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 IPE vs HE (HEA/HEB): choosing a European steel beam
All HP sizes
AISC HP-Shapes (Bearing Pile)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…