The CF CHS 139.7×3 is a circular hollow section with a mass of 10.1 kg/m, an overall depth of 139.7 mm and width of 139.7 mm and a wall thickness of 3 mm. It has a cross-sectional area of 12.9 cm², a second moment of area Iᵧ of 301 cm⁴, a plastic modulus Wₚₗ,ᵧ of 56.1 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
10.1 kg/m
Diameter
139.7 mm
Wall thickness
3 mm
Area
12.9 cm²
Ask about capacity, buckling or detailing for CF CHS 139.7×3.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CF CHS 139.7×3

Dimension symbols for CHS Cold-formed sections. Not to scale.

CF CHS 139.7×3 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh139.7
Width of sectionb139.7
Wall thicknesst3

Mass and area

Mass per metremass10.1
Cross-sectional areaA12.9

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy301
Elastic section modulus about y-axisWel,y43.1
Plastic section modulus about y-axisWpl,y56.1
Radius of gyration about y-axisiy4.83

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz301
Elastic section modulus about z-axisWel,z43.1
Plastic section modulus about z-axisWpl,z56.1
Radius of gyration about z-axisiz4.83

Torsion and warping

Torsion constant (St Venant)It602
Section modulus for torsionWt86.2

Surface area

Surface area per metreSA/m0.439
Surface area per tonneSA/t43.4m²/t

Is CF CHS 139.7×3 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 60% utilised, deflection governs
Bending33%
5.1 / 15.3 kNm
Shear5%
6.8 / 132.2 kN
Deflection60%
5.0 / 8.3 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF CHS 139.7×3

CF CHS 139.7×3 has a mass of 10.1 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 121 kg, which is the figure to use for a steel take-off or when checking a lift.

CF CHS 139.7×3 has a depth of 139.7 mm, a width of 139.7 mm, a wall thickness of 3 mm, with a cross-sectional area of 12.9 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 56.1 cm³, and the elastic modulus Wel,y is 43.1 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 20 kNm before any stability check.

The second moment of area about the major axis, Iy, is 301 cm⁴, and about the minor axis Iz is 301 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 4.83 cm about the major axis and iz is 4.83 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 4.83 cm a 0.5 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 602 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CF CHS 114.3×4CF CHS 114.3×5CF CHS 114.3×6CF CHS 114.3×6.3CF CHS 139.7×4CF CHS 139.7×5CF CHS 139.7×6CF CHS 139.7×6.3

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Cold-formed sizes
Circular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…