CivilAxisCivilAxis
☕ Support🌐 Community

CF CHS 219.1×4.5 - Section Properties

The CF CHS 219.1×4.5 is a circular hollow section with a mass of 23.8 kg/m, an overall depth of 219.1 mm and width of 219.1 mm and a wall thickness of 4.5 mm. It has a cross-sectional area of 30.3 cm², a second moment of area Iᵧ of 1750 cm⁴, a plastic modulus Wₚₗ,ᵧ of 207 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
23.8 kg/m
Diameter
219.1 mm
Wall thickness
4.5 mm
Area
30.3 cm²
Ask about capacity, buckling or detailing for CF CHS 219.1×4.5.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CF CHS 219.1×4.5

Dimension symbols for CHS Cold-formed sections. Not to scale.

CF CHS 219.1×4.5 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh219.1
Width of sectionb219.1
Wall thicknesst4.5

Mass and area

Mass per metremass23.8
Cross-sectional areaA30.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy1750
Elastic section modulus about y-axisWel,y159
Plastic section modulus about y-axisWpl,y207
Radius of gyration about y-axisiy7.59

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz1750
Elastic section modulus about z-axisWel,z159
Plastic section modulus about z-axisWpl,z207
Radius of gyration about z-axisiz7.59

Torsion and warping

Torsion constant (St Venant)It3490
Section modulus for torsionWt319

Surface area

Surface area per metreSA/m0.688
Surface area per tonneSA/t28.9m²/t

Is CF CHS 219.1×4.5 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 58% utilised, deflection governs
Bending34%
19.0 / 56.4 kNm
Shear5%
16.9 / 310.5 kN
Deflection58%
7.3 / 12.5 mm

Class 3 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF CHS 219.1×4.5

CF CHS 219.1×4.5 has a mass of 23.8 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 286 kg, which is the figure to use for a steel take-off or when checking a lift.

CF CHS 219.1×4.5 has a depth of 219.1 mm, a width of 219.1 mm, a wall thickness of 4.5 mm, with a cross-sectional area of 30.3 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 207 cm³, and the elastic modulus Wel,y is 159 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 73 kNm before any stability check.

The second moment of area about the major axis, Iy, is 1,750 cm⁴, and about the minor axis Iz is 1,750 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 7.59 cm about the major axis and iz is 7.59 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 7.59 cm a 0.8 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 3,490 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CF CHS 193.7×6.3CF CHS 193.7×8CF CHS 193.7×10CF CHS 193.7×12.5CF CHS 219.1×5CF CHS 219.1×6CF CHS 219.1×6.3CF CHS 219.1×8

Compare with other sections

Side-by-side properties against the closest equivalent in each catalogue.

vs CHS 219.1×4.5

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Cold-formed sizes
Circular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…