CivilAxisCivilAxis
☕ Support🌐 Community

CF CHS 273×6 - Section Properties

The CF CHS 273×6 is a circular hollow section with a mass of 39.5 kg/m, an overall depth of 273 mm and width of 273 mm and a wall thickness of 6 mm. It has a cross-sectional area of 50.3 cm², a second moment of area Iᵧ of 4490 cm⁴, a plastic modulus Wₚₗ,ᵧ of 428 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
39.5 kg/m
Diameter
273 mm
Wall thickness
6 mm
Area
50.3 cm²
Ask about capacity, buckling or detailing for CF CHS 273×6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CF CHS 273×6

Dimension symbols for CHS Cold-formed sections. Not to scale.

CF CHS 273×6 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh273
Width of sectionb273
Wall thicknesst6

Mass and area

Mass per metremass39.5
Cross-sectional areaA50.3

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy4490
Elastic section modulus about y-axisWel,y329
Plastic section modulus about y-axisWpl,y428
Radius of gyration about y-axisiy9.44

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz4490
Elastic section modulus about z-axisWel,z329
Plastic section modulus about z-axisWpl,z428
Radius of gyration about z-axisiz9.44

Torsion and warping

Torsion constant (St Venant)It8970
Section modulus for torsionWt657

Surface area

Surface area per metreSA/m0.858
Surface area per tonneSA/t21.7m²/t

Is CF CHS 273×6 strong enough?

Simply supported beam, uniform load, major-axis bending - to EN 1993-1-1.

Passes - 62% utilised, deflection governs
Bending28%
42.5 / 151.9 kNm
Shear6%
30.9 / 515.5 kN
Deflection62%
9.5 / 15.3 mm

Class 2 section. ULS uses γQ = 1.5 on the load you enter; deflection uses the unfactored load against L/360. Lateral-torsional buckling is not included - the compression flange is assumed restrained.

Common questions about CF CHS 273×6

CF CHS 273×6 has a mass of 39.5 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 474 kg, which is the figure to use for a steel take-off or when checking a lift.

CF CHS 273×6 has a depth of 273 mm, a width of 273 mm, a wall thickness of 6 mm, with a cross-sectional area of 50.3 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 428 cm³, and the elastic modulus Wel,y is 329 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 152 kNm before any stability check.

The second moment of area about the major axis, Iy, is 4,490 cm⁴, and about the minor axis Iz is 4,490 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 9.44 cm about the major axis and iz is 9.44 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 9.44 cm a 0.9 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 8,970 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CF CHS 244.5×16CF CHS 273×4CF CHS 273×4.5CF CHS 273×5CF CHS 273×6.3CF CHS 273×8CF CHS 273×10CF CHS 273×12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section
All CHS Cold-formed sizes
Circular Hollow Sections - Cold-formed (BS EN 10219)
Full steel section tables
Every UB, UC, hollow, channel & angle section
Open the interactive tool
Search, compare & run EC3 capacity checks
Rate this
No ratings yet
Sign in to join the discussion.
Loading…