CivilAxisCivilAxis
☕ Support🌐 Community

CF CHS 406.4×6 - Section Properties

The CF CHS 406.4×6 is a circular hollow section with a mass of 59.2 kg/m, an overall depth of 406.4 mm and width of 406.4 mm and a wall thickness of 6 mm. It has a cross-sectional area of 75.5 cm², a second moment of area Iᵧ of 15100 cm⁴, a plastic modulus Wₚₗ,ᵧ of 962 cm³, tabulated by CivilAxis from BS EN 10219-2:2006 (SCI P363 Blue Book).

Mass
59.2 kg/m
Diameter
406.4 mm
Wall thickness
6 mm
Area
75.5 cm²
Ask about capacity, buckling or detailing for CF CHS 406.4×6.
🔍 Open the full Steel Catalogue📖 Design theory📐 Worked example
or pick a unit on any row
CHS Cold-formed section profile showing the dimension symbols used for CF CHS 406.4×6

Dimension symbols for CHS Cold-formed sections. Not to scale.

CF CHS 406.4×6 section properties to BS EN 10219-2:2006.

Geometry

Depth of sectionh406.4
Width of sectionb406.4
Wall thicknesst6

Mass and area

Mass per metremass59.2
Cross-sectional areaA75.5

Bending about the major axis (y-y)

Area moment of inertia about y-axisIy15100
Elastic section modulus about y-axisWel,y745
Plastic section modulus about y-axisWpl,y962
Radius of gyration about y-axisiy14.2

Bending about the minor axis (z-z)

Area moment of inertia about z-axisIz15100
Elastic section modulus about z-axisWel,z745
Plastic section modulus about z-axisWpl,z962
Radius of gyration about z-axisiz14.2

Torsion and warping

Torsion constant (St Venant)It30300
Section modulus for torsionWt1490

Surface area

Surface area per metreSA/m21.6

Common questions about CF CHS 406.4×6

CF CHS 406.4×6 has a mass of 59.2 kg/m, tabulated to BS EN 10219-2:2006. A 12 m length therefore weighs about 710 kg, which is the figure to use for a steel take-off or when checking a lift.

CF CHS 406.4×6 has a depth of 406.4 mm, a width of 406.4 mm, a wall thickness of 6 mm, with a cross-sectional area of 75.5 cm². These are the nominal dimensions from BS EN 10219-2:2006; rolling tolerances apply to the delivered section.

The plastic section modulus about the major axis, Wpl,y, is 962 cm³, and the elastic modulus Wel,y is 745 cm³. Wpl,y is what sets the moment capacity of a Class 1 or 2 section: M_pl,Rd = Wpl,y x f_y / gamma_M0, so at S355 with gamma_M0 = 1.0 this section reaches about 342 kNm before any stability check.

The second moment of area about the major axis, Iy, is 15,100 cm⁴, and about the minor axis Iz is 15,100 cm⁴. Iy is the value deflection depends on - for a simply supported beam under a uniform load, the midspan deflection is 5wL⁴/384EIy - so on spans where a deflection limit governs rather than strength, this is the number that decides the section.

iy is 14.2 cm about the major axis and iz is 14.2 cm about the minor axis. Column buckling is governed by the SMALLER value: the slenderness is lambda = L_cr / i, so with iz = 14.2 cm a 1.4 m effective length already gives lambda = 100. Minor-axis buckling almost always controls unless the weak axis is restrained.

The St Venant torsion constant It is 30,300 cm⁴. Closed sections carry torsion in a shear flow around the perimeter, which makes them far stiffer in torsion than an open section of the same weight and is usually why one is specified.

Related CHS Cold-formed sizes

CF CHS 355.6×10CF CHS 355.6×12CF CHS 355.6×12.5CF CHS 355.6×16CF CHS 406.4×6.3CF CHS 406.4×8CF CHS 406.4×10CF CHS 406.4×12

Learn more

📘 How to read a steel section table (UB, UC, IPE, HE)📘 Section modulus explained: elastic (Wel) vs plastic (Wpl)📘 SHS vs RHS vs CHS: choosing a hollow steel section